基于水力模型的建筑加压调蓄系统能耗评估及优化研究

Study on Energy Consumption Assessment and Optimization of Building Pressurized Storage System Based on Hydraulic Model

孙良志 1袁展 2谢小风 3方婷婷 3杨凤伟 3杨坤 2舒诗湖1

作者信息

  • 1. 东华大学环境科学与工程学院,上海 201620
  • 2. 上海城市水资源开发利用国家工程中心有限公司,上海 200082
  • 3. 上海城投水务(集团)有限公司自来水业务受理分公司,上海 200042
  • 折叠

摘要

Abstract

The energy consumption of building pressurized storage system occupies a large proportion in building energy consumption,and pumping unit optimization and energy consumption control have become one of the re-search focuses in the industry.Based on hydraulic model,the current situation on the water supply system from the second to seventh floors of a nursing home building in Shanghai was modeled and checked.According to the water consumption characteristics,energy-saving optimization schemes were proposed and the energy consumption of pumping unit operation was evaluated in different water supply modes.The results show that the current frequency conversion pump selection of the nursing home is too conservative,resulting in a large energy waste;Under the single pump condition,the same type of variable frequency pump is more energy efficient than the power frequency pump,and the stacking equipment can save 67.8%of the energy consumption compared with the operation of the variable frequency pump.Under the double-pump condition,two frequency conversion pumps with the same frequency speed control can effectively control energy consumption.Compared with the parallel water supply of operating energy,its frequency conversion pumps and power frequency pumps,it savings energy consumption by 9.1%,but it still can't get rid of the effect in a low-flow non-efficient area;However,the use of frequency conversion pumps and power frequency small pumps combination of water supply can be effectively utilized power frequency small pumps transi-tion inefficient area.Compared with the full frequency conversion,its energy consumption saved by 18.4%.However,under the actual double-pump operation conditions,it is necessary to choose the water supply mode according to the pump room's automatic control system conditions compromise.

关键词

建筑加压调蓄系统/水力模型/能耗评估/节能优化

Key words

building pressurized storage system/hydraulic model/assessment of energy consumption/energy-saving optimization

分类

土木建筑

引用本文复制引用

孙良志,袁展,谢小风,方婷婷,杨凤伟,杨坤,舒诗湖..基于水力模型的建筑加压调蓄系统能耗评估及优化研究[J].市政技术,2024,42(12):15-22,8.

基金项目

国家重点研发计划(2021YFC3201303) (2021YFC3201303)

市国资委企业创新发展和能级提升项目(2022031) (2022031)

上海城投水务(集团)有限公司科研项目计划(KY.YW.22.001) (集团)

市政技术

1009-7767

访问量0
|
下载量0
段落导航相关论文