家电科技Issue(z1):41-45,5.DOI:10.19784/j.cnki.issn1672-0172.2024.99.009
R290水循环式空调系统性能优化分析
Performance optimization analysis of R290 water cycle air conditioning system
张凯强 1马国远1
作者信息
- 1. 北京工业大学制冷与低温工程系 北京 100124
- 折叠
摘要
Abstract
The water circulation air conditioning system using R290 as the working fluid effectively solves the safety problem of R290 air conditioning by using plate heat exchangers to deliver the cooling capacity indoors without the working fluid entering the house.This article establishes an ε-NTU model of the system to simulate and analyze the influence of indoor heat exchanger air volume and water circulation on system performance.The results show that the heat capacity flow rate of circulating water is equal to that of air,which can improve the temperature efficiency of the heat exchanger in most cases.A control method that can accurately control the pump flow rate by only measuring the system temperature is also proposed,which can serve as a basis for optimizing the design of water circulation air conditioning systems.关键词
R290/水循环式空调/板式换热器/ε-NTU方法/流量控制Key words
R290/Water circulation air conditioning/Heat Exchanger/ε-NTU method/Flow control分类
信息技术与安全科学引用本文复制引用
张凯强,马国远..R290水循环式空调系统性能优化分析[J].家电科技,2024,(z1):41-45,5.