家电科技Issue(z1):549-552,4.DOI:10.19784/j.cnki.issn1672-0172.2024.99.116
交流吸油烟机异音控制研究
Research on abnormal sound control of AC kitchen hood
黄鹏 1胡杨 1王小龙 1周伟峰 1林辉1
作者信息
- 1. 华帝股份有限公司 广东 中山 528415
- 折叠
摘要
Abstract
The AC motor has the advantages of simple structure,high reliability and low cost,and is widely used in the range hood products.However,du e to the inherent properties of the AC motor,many range hood products equipped with the AC motor appear 100 Hz and 200 Hz motor resonance"buzz",which will seriously affect the customer experience and reduce product quality.Through the combination of dichotomy and spectrum analysis,rapid qualitative and quantitative analysis of the abnormal sound,through the combination of motor shock pad matching and sheet metal structure optimization,effectively eliminate the kitchen hood motor sound.关键词
交流电机/频谱分析/减震垫匹配/钣金结构优化Key words
AC motor/Spectrum analysis/Shock pad matching/Sheet metal structure optimization分类
信息技术与安全科学引用本文复制引用