| 注册
首页|期刊导航|家电科技|定速除湿机压缩机停机时吸气管应力分析及优化

定速除湿机压缩机停机时吸气管应力分析及优化

秦文超 张洋 郝玉密 朱标 陈守海 张江

家电科技Issue(z1):553-556,4.
家电科技Issue(z1):553-556,4.DOI:10.19784/j.cnki.issn1672-0172.2024.99.117

定速除湿机压缩机停机时吸气管应力分析及优化

Stress analysis and optimization of suction pipe during compressor shutdown of constant speed dehumidifier

秦文超 1张洋 1郝玉密 1朱标 1陈守海 1张江1

作者信息

  • 1. 海信空调有限公司 山东 青岛 266000
  • 折叠

摘要

Abstract

When a certain dehumidifier compressor is shut down,the stress in the suction pipe exceeds the enterprise standard limit.This article uses a combination of simulation and testing methods to study the mechanism of the high stress in the suction pipe during compressor shutdown.Transient simulation analysis is used to analyze the stress in the suction pipe during compressor shutdown.The maximum position of the simulation stress is basically consistent with the test,and the maximum error is controlled within 10%.The position of the pipeline damper is optimized,and the problem of excessive shutdown stress is solved,shortening the development cycle and improving design efficiency.

关键词

除湿机/吸气管/停机/应力/瞬态分析

Key words

Dehumidifier/Suction pipe/Shutdown/Stress/Transient analysis

分类

信息技术与安全科学

引用本文复制引用

秦文超,张洋,郝玉密,朱标,陈守海,张江..定速除湿机压缩机停机时吸气管应力分析及优化[J].家电科技,2024,(z1):553-556,4.

家电科技

1672-0172

访问量0
|
下载量0