家电科技Issue(z1):175-179,5.DOI:10.19784/j.cnki.issn1672-0172.2024.99.036
吸气干度对R32转子式压缩机性能影响的实验研究
Experimental study on the R32 rotary compressor performance of different suction refrigerant quality
孟亚飞 1廖四清 1陈磊1
作者信息
- 1. 广东美芝制冷设备有限公司 广东 佛山 528300||美的集团股份有限公司 广东 佛山 528300
- 折叠
摘要
Abstract
To study the effect of suction refrigerant quality on R32 rotary compressor performance,the calorimeter method with the function of suction refrigerant quality was used to study the performance of compressor by changing the suction refrigerant quality and analyzing theoretical refrigeration cycle.The results showed that:under the condition of superheating,the suction state had little effect on the compressor's volumetric efficiency and isentropic efficiency.Under the condition of two-phase,the compressor's volumetric efficiency and isentropic efficiency decreased with decreasing suction refrigerant quality.Compared to refrigerant superheating suction,the decay ratios of volumetric efficiency and isentropic efficiency were 3.3%,8.0%,and 8.3%,14.8%,for suction refrigerant quality ratios of 0.94,0.88.The actual compressor discharge temperature had a linear correlation with the suction refrigerant quality.Under the condition of two-phase,the mass flow rate is affected by suction density and volumetric efficiency.The capacity and EER had a maximum value at a suction refrigerant quality ratio of 1.Under the condition of two-phase,the attenuation of volumetric efficiency and isentropic efficiency changes the trend of EER curve.关键词
吸气干度/转子式压缩机/容积效率/等熵效率/排气温度/EERKey words
Suction refrigerant quality/Rotary compressor/Volumetric efficiency/Isentropic efficiency/Discharge temperature/EER分类
信息技术与安全科学引用本文复制引用
孟亚飞,廖四清,陈磊..吸气干度对R32转子式压缩机性能影响的实验研究[J].家电科技,2024,(z1):175-179,5.