首页|期刊导航|南方电网技术|基于LM算法的CRDS绝缘气体特征分解产物H2S检测技术

基于LM算法的CRDS绝缘气体特征分解产物H2S检测技术OA北大核心CSTPCD

H2S Detection Technology of CRDS Insulating Gas Characteristic Decomposition Products Based on LM Algorithm

中文摘要英文摘要

光腔衰荡光谱法(cavity ring-down spectroscopy,CRDS)以其灵敏度高、检测速度快等优势,被应用于绝缘气体特征分解组分H2S的在线检测领域,对绝缘电气设备的故障状态诊断具有重要意义.衰荡时间作为进行浓度计算的关键参数,如何拟合出衰荡曲线实现衰荡时间的准确求解成为该技术领域的一大难点.而衰荡曲线的高精度拟合算法是决定CRDS精度的关键因素,选取STM32F407型号的单片机建立衰荡曲线模型,通过列文伯格-马夸尔特(Levenberg-Marquardt,LM)算法对H2S气体在1 578.1 nm处采集到的衰荡信号进行拟合并搭建CRDS实验平台进行验证,基于LM算法进行了仿真与实验,同时与最小二乘法进行对比.仿真结果显示,单片机拟合决定系数R2达到了0.996,与离线软件平台高度接近.在不同的气体浓度下的实验结果表明,拟合精度呈上升趋势.通过浓度标定实验实现了微量H2S的准确测量,气体实际值与测量值的相关系数为0.992 5,结果的绝对误差不超过0.5×10-6.与基于最小二乘法的浓度测量结果相比,基于LM算法的浓度数据均方根值更小,检测准确性更高.

With the high sensitivity and fast detection speed of cavity ring-down spectroscopy(CRDS),CRDS has been applied to the field of online detection of H2S of characteristic decomposition components of insulating gases,which is of great significance for the fault state diagnosis of insulated electrical equipment.Ring-down time as the key parameter for concentration calculation,how to fit the ring-down curve to achieve the accurate solution of the ring-down time has become a major difficulty in this technical field.The high-precision fitting algorithm of the decay curve is the key factor determining the accuracy of CRDS.STM32F407 models of single-chip microcomputers are selected to establish the decay curve model,and the Levenberg-Marquardt(LM)algorithm is used to fit and combine the attenuation signals collected by H2S gas at 1578.1nm to build a CRDS experimental platform for verification.Simulations and experiments are conducted based on the LM algorithm,and compared with the least squares method.The simulation results show that the coefficient of determination R2 of the microcontroller fitting reaches 0.996,which is highly close to the offline software platform.The experimental results at different gas concentrations show that the fitting accuracies show an increasing trend.The accurate measurement of trace H2S is achieved by concentration calibration experiment,the correlation coefficient between the actual value of the gas and the measured value is 0.9925,and the absolute errors of the result do not exceed 0.5×10-6.Compared with the concentration measurement results based on the least squares method,the root mean square values of the concentration data based on the LM algorithm are smaller and the detection accuracies are higher.

张欣冉;吴芳芳;吕浩楠;钱文超;蒋安昊;张潮海

南京航空航天大学自动化学院,南京 211106浙江华电器材检测研究院有限公司,杭州 311100南京航空航天大学自动化学院,南京 211106南京航空航天大学自动化学院,南京 211106南京航空航天大学自动化学院,南京 211106南京航空航天大学自动化学院,南京 211106

动力与电气工程

光腔衰荡光谱法列文伯格-马夸尔特算法STM32单片机衰荡时间非线性拟合

cavity ring-down spectroscopy(CRDS)Levenberg-Marquardt(LM)algorithmsSTM32 microcontrollerring-down timenonlinear fitting

《南方电网技术》 2024 (11)

141-149,168,10

国家重点研发计划资助项目(2021YFF0603100)浙江省领军型创新创业团队项目(2019R01014). Supported by National Key Research and Development Program of China(2021YFF0603100)the Project of Zhejiang Provincial Leading Innovation and Entrepreneurship Team(2019R01014).

10.13648/j.cnki.issn1674-0629.2024.11.015

评论