重庆大学学报2024,Vol.47Issue(12):13-23,11.DOI:10.11835/j.issn.1000.582X.2024.12.002
耦合中置式光伏Trombe墙的室内热舒适性评价
Indoor thermal comfort evaluation of a room coupled with built-middle PV-Trombe wall
摘要
Abstract
A thermal comfort evaluation model,based on energy balance principles,is developed for assessing indoor thermal comfort in a room equipped with a built-middle PV-Trombe wall during the heating season.The study also investigates how the installation location of the absorber plate affects indoor thermal comfort.Results show that while the built-middle PV-Trombe wall improves indoor thermal comfort,it maintains only a basic level of comfort overall.Between 9:00 and 13:00,the indoor environment remains cold,resulting in occupant discomfort.However,when solar radiation is low,the enclosed air layer formed by the photovoltaic panel and glass cover can still help maintain a more comfortable room temperature.Positioning the absorber plate on the outer surface of the massive wall enhances the indoor thermal environment,reducing discomfort duration by one hour without additional costs.The thermal comfort evaluation model constructed here allows for easy prediction of indoor thermal comfort variations over time,facilitating dynamic management of indoor temperature.关键词
光伏Trombe墙/室内热环境/热舒适性/标准有效温度/评价模型Key words
PV-Trombe wall/indoor environment/thermal comfort/standard effective temperature/evaluation model分类
能源科技引用本文复制引用
杨宏亮,秦靓靓,吴双应..耦合中置式光伏Trombe墙的室内热舒适性评价[J].重庆大学学报,2024,47(12):13-23,11.基金项目
重庆市技术创新与应用发展专项项目(cstc2019jscx-msxmX0213). Supported by the Project of Technological Innovation and Application Development of Chongqing(cstc2019jscx-msxmX0213). (cstc2019jscx-msxmX0213)