| 注册
首页|期刊导航|实验动物与比较医学|6种复合固定液对金黄仓鼠视网膜组织固定效果的比较

6种复合固定液对金黄仓鼠视网膜组织固定效果的比较

吴海凤 周小江 李晨江 李怀银 高明

实验动物与比较医学2024,Vol.44Issue(6):675-681,7.
实验动物与比较医学2024,Vol.44Issue(6):675-681,7.DOI:10.12300/j.issn.1674-5817.2024.049

6种复合固定液对金黄仓鼠视网膜组织固定效果的比较

Comparison of the Fixation Effects of Six Composite Fixatives on Retinal Tissue of Golden Hamsters

吴海凤 1周小江 1李晨江 1李怀银 1高明1

作者信息

  • 1. 兰州生物制品研究所有限责任公司,甘肃省疫苗工程技术研究中心,兰州 730046
  • 折叠

摘要

Abstract

Objective To compare the effects of six composite fixatives on paraffin sections of golden hamster retinal tissue,and to optimize the fixation methods for retinal tissue paraffin sections of golden hamsters.Methods Eighteen male SPF grade golden hamsters were taken and randomly divided into six groups of three animals each.After each animal was anesthetized by intraperitoneal injection of sodium pentobarbital,cardiac perfusion was performed using 4%paraformaldehyde,Bouin's,Carnoy,Davidson's,Zenker,and Helly fixatives,respectively.The eye tissues of each animal were taken out to make eye cups and put into the corresponding compound fixative solution for fixation,and then taken out for paraffin embedding after 48 h.The embedded blocks were sliced using microtome,and then stained with hematoxylin and eosin(HE).The morphological characteristics of retinal tissue cells were observed under a light microscope and scored in a double-blind method to statistically analyze the fixation effect and staining quality of various composite fixative solutions.Results Retinal sections fixed with Davidson's fixative exhibited intact morphology without breaks,clear structural layers,well-morphosed nuclei,and tight adhesion between the retina,sclera,and uvea.In contrast,sections fixed with 4%paraformaldehyde,Bouin's,and Carnoy fixatives showed varying degrees of retinal breaks and detachment from the sclera.Sections fixed with Zenker and Helly fixatives demonstrated the poorest quality,characterized by pronounced detachment,large fissures,unclear cell layers,and pale staining.Statistical analysis using SPSS 27.0 software revealed significant differences in mean scores among the six fixatives(P<0.001).The fixation quality ranking was as follows:Davidson's fixative>4%paraformaldehyde>Bouin's fixative>Carnoy fixative>Helly fixative>Zenker fixative.Zenker and Helly fixatives showed significantly lower scores than the other fixatives(P<0.001),while no significant differences were observed among the remaining fixatives(P>0.05).Conclusion Davidson's fixative provides the best fixation and staining results,followed by 4%paraformaldehyde and Bouin's fixative.Carnoy fixative exhibits suboptimal performance,while Zenker and Helly fixatives result in the poorest outcomes.Therefore,Davidson's fixative is recommended as the optimal fixative for golden hamster retinal tissue,with 4%paraformaldehyde,Bouin's and Carnoy fixatives as alternative options.

关键词

固定液/金黄仓鼠/视网膜/石蜡切片

Key words

Fixative solution/Golden hamster/Retinal/Paraffin section

分类

医药卫生

引用本文复制引用

吴海凤,周小江,李晨江,李怀银,高明..6种复合固定液对金黄仓鼠视网膜组织固定效果的比较[J].实验动物与比较医学,2024,44(6):675-681,7.

实验动物与比较医学

OACSTPCD

1674-5817

访问量0
|
下载量0
段落导航相关论文