喷淋装置对南方地区自然通风奶牛舍热环境改善效果的数值模拟研究OA北大核心
Study on the improvement effect of spray device on the thermal environment of naturally ventilated dairy barn in southern China
本研究针对我国南方地区夏季自然通风牛舍内奶牛热应激严重的问题,利用现场实测和计算流体动力学(CFD)的研究方法,对南方地区某自然通风奶牛舍3种不同外界风向、风速、温度和湿度条件下,加入喷淋装置前后,舍内的风速场、THI场进行对比分析.结果表明:1)温度场各个测点的相对误差范围为0.04%~1.36%,平均相对误差0.43%.相对湿度场各个测点的相对误差范围为0~7.43%,平均相对误差2.22%.剔除异常值后,气流场各个测点的相对误差范围为0.05%~83.68%,平均相对误差38.44%.2)数值模拟表明,高风速区主要集中在饲喂走道、牛舍边缘部分,风速为1.4~3.0 m/s,低风速区主要集中在牛舍东侧奶牛活动区域,将近一半奶牛身体附近风速低于0.4 m/s.不同风向对于牛舍边缘的影响程度不同,东北风与南风情况下牛舍东部出现高风速区,西北风情况下牛舍边缘气流场比较均匀.3)加入喷淋装置后,外界气候不同会导致喷淋造成的效果不同,当温湿度适中风速相对较小,喷淋装置的加入会使温湿度指数上升0.23,差异显著(P<0.05),加剧奶牛热应激;当风速较大,高温低湿时,喷淋装置的加入会使温湿度指数下降0.97,差异显著(P<0.05);当风速较大低温高湿时,喷淋装置的加入会使温湿度指数下降0.19,差异不显著(P>0.05).综上,本研究模拟了在3种不同外界环境下喷淋装置的加入对于牛舍热环境的改变和舍内奶牛热应激的改善情况,可为 自然通风奶牛舍设计及舍内热环境调控提供依据.
The study focuses on the severe heat stress of dairy cows in natural ventilation cowshed in summer in southern China.Using on-site measurements and computational fluid dynamics(CFD)research methods,a comparative analysis was conducted on the the wind speed field and THI field in a natural ventilation cowshed before and after the addition of the spray device under three different external wind directions,wind speeds,temperature and humidity conditions in a natural ventilation cowshed in southern China.The results showed that:1)The relative error range of each measuring point in the temperature field was 0.04%-1.36%,with an average relative error of 0.43%.The relative error range of each measuring point in the relative humidity field was 0.00-7.43%,with an average relative error was 2.22%.After removing the abnormal values,the relative error range of each measuring point in the air flow field was 0.05%-83.68%,with an average relative error of 38.44%.2)Numerical simulation showed that the high wind speed area was mainly concentrated in the feeding aisle and the edge of the cowshed,ranging from 1.4 to 3.0 m/s.The low wind speed area was mainly concentrated in the cow activity area on the east side of the cowshed,with nearly half of the cows having wind speed below 0.4 m/s.The influence of different wind directions on the edge of the cowshed was different.Under northeast and south wind conditions,there was a high wind speed area in the east of the cowshed,while under northwest wind conditions,the airflow field at the edge of the cowshed was relatively uniform.3)After adding a sprinkler system,different external climates can lead to different effects of spraying.When the temperature and humidity were moderate and the wind speed was relatively small,the addition of the spray device will increase the temperature and humidity index by 0.23,which was significant(P<0.05)and exacerbates the heat stress of dairy cows.When the wind speed was high,high temperature and low humidity,the addition of the spray device will decrease the temperature and humidity index by 0.97,and the difference was significant(P<0.05).When the wind speed was high,low temperature and high humidity,the addition of the spray device will decrease the temperature and humidity index by 0.19,and the difference was not significant(P>0.05).In summary,this study simulated the changes in the thermal environment of the cow house and the improvement of the heat stress of the cows in the house by adding the spray device in three different external environments.The results can provide a basis for the design of naturally ventilated dairy cowshed and the regulation of the thermal environment in the dairy cowshed.
段巧敏;孙禹枫;张海亮;杨桐桐;王泽;李俊哲;李籽林;肖卫明;王雅春
中国农业大学动物科学技术学院,北京 100193浙江一鸣食品股份有限公司浙江省奶牛遗传改良与乳品质研究重点实验室,浙江温州 325000
畜牧业
CFD自然通风奶牛舍喷淋装置温湿度指数
CFDnatural ventilationdairy cowshedspraying devicetemperature and humidity index
《中国农业大学学报》 2025 (002)
139-150 / 12
国家现代农业产业技术体系(CARS-36);长江学者和创新团队发展计划(IRT_15R62)
评论