| 注册
首页|期刊导航|日用化学工业(中英文)|高效液相色谱法测定α-烯基磺酸盐中的磺内酯

高效液相色谱法测定α-烯基磺酸盐中的磺内酯

张红 姚晨之 薛伟 曹圣悌 公培龙

日用化学工业(中英文)2025,Vol.55Issue(1):104-109,6.
日用化学工业(中英文)2025,Vol.55Issue(1):104-109,6.DOI:10.3969/j.issn.2097-2806.2025.01.013

高效液相色谱法测定α-烯基磺酸盐中的磺内酯

Determination of sultones in α-olefin sulfonate by high performance liquid chromatography

张红 1姚晨之 2薛伟 3曹圣悌 4公培龙5

作者信息

  • 1. 中国日用化学工业研究院,山西 太原 030001||功能性表面活性剂山西省重点实验室,山西 太原 030001
  • 2. 中国日用化学工业研究院,山西 太原 030001||中轻检验认证(太原)有限公司,山西 太原 030001||功能性表面活性剂山西省重点实验室,山西 太原 030001
  • 3. 中国日用化学工业研究院,山西 太原 030001||中轻检验认证(太原)有限公司,山西 太原 030001
  • 4. 中国日用化学工业研究院,山西 太原 030001
  • 5. 中轻检验认证(太原)有限公司,山西 太原 030001
  • 折叠

摘要

Abstract

A method for the determination of sultones in α-olefin sulfonate by high performance liquid chromatography(HPLC)was developed.This method was used to monitor the risk of 4 batches of α-olefin sulfonate samples on the market.The samples were dissolved in water and ethanol,and then extracted with petroleum ether.The extracts were dissolved in the mixed solution of n-hexane and isopropyl alcohol,and the equal degree elution was performed using n-hexane and isopropyl alcohol as the mobile phase by high performance liquid chromatography.The volume ratio of n-hexane to isopropyl alcohol was 8∶2.The extracts were separated by Inertsil CN-3 column(250 mm×4.6 mm×5µm)at the flow rate of 2.0 mL/min.The injection volume was 20µL and the column temperature was 25℃.The detector was the evaporative light scattering detector.The temperature of the drift tube was 80℃,and the flow rate of carrier gas was 2.0 L/min.The quantitative method was external standard method.The results show that the mass concentration of sultones in the range of 80-200 μg/mL shows a good linear relationship,and the detection limit is 5.25 μg/mL with the correlation coefficient greater than 0.989.The relative standard deviation is 1.01%(n=6).The recoveries of sultones are 102.82%-108.24%.The method has good separation effect,good linear relationship,simple operation,high sensitivity,and good accuracy and repeatability.The method can quickly and accurately measure the residual amount of sultones in α-olefin sulfonate.

关键词

高效液相色谱/蒸发光散射检测器/α-烯基磺酸盐/磺内酯

Key words

high performance liquid chromatography/evaporative light scattering detector/α-olefin sulfonate/sultones

分类

化学化工

引用本文复制引用

张红,姚晨之,薛伟,曹圣悌,公培龙..高效液相色谱法测定α-烯基磺酸盐中的磺内酯[J].日用化学工业(中英文),2025,55(1):104-109,6.

基金项目

中国轻工集团公司科技创新基金项目(ZQ2022JC-GG02) (ZQ2022JC-GG02)

溢多利研究基金资助项目(VTR2021) (VTR2021)

自然堂研究基金资助项目(自然堂2021) (自然堂2021)

日用化学工业(中英文)

OA北大核心

1001-1803

访问量0
|
下载量0
段落导航相关论文