Permanent Magnet Synchronous Motor(PMSM)is widely used in many industrial fields because of its good control performance and high power density.The PMSM inductance is greatly affected by the saturation of working conditions,making online inductance identification important.Most traditional online inductance identification algorithms for PMSM are implemented based on the dq-axis model,which relies on the accurate rotor position.If a bias is caused by sensorless control or position sensor error,the accuracy of the traditional inductance identification method can not be guaranteed.This paper proposes an online identification method for PMSM inductance decoupling from the rotor position error. Firstly,the impedance characteristics of the PMSM inductance under the complex frequency domain are analyzed.The virtual-axis impedance model decoupling from the rotor position is constructed according to the inductance-changing characteristics at different rotor positions.Then,the inductance estimation strategy based on the high-frequency(HF)injection under the virtual axis is proposed.The whole HF injection is realized based on the dq-axis injection with the coordination transformation.The HF injected and responding signal is extracted by the fast Fourier transform(FFT).Finally,the dq-axis inductance identification is realized by searching the peak values of the virtual-axis inductance to avoid the influence of the rotor position error.Furthermore,the construction strategy of the virtual axis and the amplitude-frequency selection strategy of the injected signal are analyzed. A 2.2 kW interior PMSM test platform was built.The experimental results show that the proposed method can realize the inductance identification under different online operating conditions,which is immune to the rotor position error.Different working conditions are tested(from no-load to full-load at 15 Hz and 25 Hz)to verify the robustness of the method.Herein,the signal sampling and identification period by DFT is constant.Meanwhile,the inductance surfaces under different working conditions(different combinations of id and iq)are obtained.The inductance changes obviously under different working conditions.Compared with the unsaturated inductance,the variation range of Ld,q can reach up to 13.1%and 10.2%.The identification errors of Ld,q under different id,q combinations can be reduced to less than 5.1%and 3.6%,respectively,showing the accuracy of the proposed method. The conclusions can be drawn from the experimental results.(1)The proposed method based on the virtual-axis HF impedance model is independent of the rotor position,which is suitable for applications with rotor position error.(2)The accuracy of the inductance identification can be guaranteed through the construction strategy of the virtual axis and the amplitude-frequency selection strategy.

关键词

永磁同步电机/电感在线辨识/高频信号注入/等效阻抗模型/转子位置误差解耦

Key words

Permanent magnet synchronous motor(PMSM)/online inductance identification/high frequency signal injection/equivalent impedance model/rotor position error decoupling

分类

信息技术与安全科学

引用本文复制引用

王奇维,李斌兴,潘冠丞,王高林,徐殿国..基于转子位置误差解耦阻抗建模的永磁同步电机电感在线辨识方法[J].电工技术学报,2025,40(2):439-451,13.

基金项目

国家自然科学基金青年科学基金(52307048)、台达电力电子科教发展计划科研项目(DREG2024008)和黑龙江省博士后项目(LBH-Z23022)资助. (52307048)

电工技术学报

OA北大核心

1000-6753

访问量0
|
下载量0
段落导航相关论文