| 注册
首页|期刊导航|云南水力发电|董艾倒虹吸设计方案分析

董艾倒虹吸设计方案分析

郑峥

云南水力发电2025,Vol.41Issue(2):74-76,3.
云南水力发电2025,Vol.41Issue(2):74-76,3.DOI:10.3969/j.issn.1006-3951.2025.02.019

董艾倒虹吸设计方案分析

Analysis of Dongai Inverted Siphon Design Scheme

郑峥1

作者信息

  • 1. 安徽省水利水电勘测设计研究总院有限公司,安徽 合肥 230088
  • 折叠

摘要

Abstract

In order to review the feasibility of the design scheme for the Da Gou Dong Ai inverted siphon structure in the middle section of the Malagou section of the Huaihong New River Irrigation District,and provide design basis for later construction,this article takes the design of the inverted siphon pipeline as the analysis object on the basis of the project layout,and conducts pipe material selection,hydraulic calculation,and pipe jacking force calculation for the project.The conclusion shows that the head loss,overcurrent capacity,and stability calculation all meet the requirements,and the structural design is reasonable.

关键词

灌区/倒虹吸/设计方案/顶管

Key words

irrigation district/inverted siphon/design proposal/pipe-jacking

分类

建筑与水利

引用本文复制引用