电力勘测设计Issue(2):24-28,92,6.DOI:10.13500/j.dlkcsj.issn1671-9913.2025.02.005
槽式光热电站集热回路流量不均影响分析
Study on Influence of Uneven flow Distribution Among Collector Circuits of Trough Solar Thermal Power Plant
康宁 1李栋 1徐皓鹏 1靳伯阳1
作者信息
- 1. 中国电力工程顾问集团华北电力设计院有限公司,北京 100120
- 折叠
摘要
Abstract
A modeling study on heat transfer fluid system of 50 MW parabolic trough solar thermal power plant is conducted using AFT Fathom.The simulation of heat transfer fluid flow distribution in the collector circuits is proposed under three low flow conditions.In this simulation,the operation parameters,such as DNI value,meteorological condition,site condition,layout of the heat collection field and operation mode are all based on the actual data of a certain project.The simulation results show that uneven flow distribution exists among collector circuits under low flow conditions.Discontinuous flow appears in some circuits under the lowest 8.4%design point flow condition.Based on the collector control strategy,impacts of the uneven flow distribution on power generation are estimated.Under 33.5%and 16.8%design point conditions,decreases in power generation are not significant.While under 8.4%design point condition,the power generation decreases by 20.65%,indicating a significant impact.关键词
太阳能电站/集热回路/流动模拟/流量分配/发电量Key words
solar power plant/collector circuit/flow simulation/flow distribution/power generation分类
动力与电气工程引用本文复制引用
康宁,李栋,徐皓鹏,靳伯阳..槽式光热电站集热回路流量不均影响分析[J].电力勘测设计,2025,(2):24-28,92,6.