高通量固相萃取-超高效液相色谱-串联质谱法测定血清中17种全氟/多氟烷基化合物

林强 王健 李晶晶 苏东霞 李美丽 王佳 牛宇敏 邵兵

色谱2025,Vol.43Issue(3):252-260,9.
色谱2025,Vol.43Issue(3):252-260,9.DOI:10.3724/SP.J.1123.2024.03007

高通量固相萃取-超高效液相色谱-串联质谱法测定血清中17种全氟/多氟烷基化合物

Determination of 17 perfluorinated/polyfluoroalkyl compounds in serum by high-throughput solid-phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry

林强 1王健 2李晶晶 1苏东霞 1李美丽 1王佳 1牛宇敏 3邵兵3

作者信息

  • 1. 北京市延庆区疾病预防控制中心,北京 102100
  • 2. 北京市延庆区永宁社区卫生服务中心,北京 102100
  • 3. 北京市疾病预防控制中心,食物中毒诊断溯源技术北京市重点实验室,北京 100013||首都医科大学公共卫生学院,北京 100069
  • 折叠

摘要

Abstract

Perfluorinated/polyfluoroalkyl compounds(PFASs)are a group of synthetic chemi-cals.Since the 1940s,PFASs have been widely used in industrial and daily consumer fields.PFASs can enter the human body through various pathways,such as drinking water,food,and air.Toxicological studies have shown that PFASs feature developmental and reproductive toxic-ity.Thus,the accurate assessment of PFAS exposure levels plays an important role in determi-ning the health risks of these compounds.Biological monitoring is considered the most ideal means of monitoring and evaluating PFAS levels in the human body.The concentration of PFASs in serum can directly reflect their level of absorption in the human body after exposure;therefore,serum is widely used as a biological matrix for evaluating PFASs. In this study,a high-throughput solid-phase extraction(SPE)-ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)was developed for the determi-nation of 17 PFASs in serum.A laboratory-made straight-through SPE column was used to puri-fy serum samples.The SPE column used a new inorganic material with a low perfluorinated compound background.Unlike traditional SPE columns,the extraction column does not require activation before use,and the sample can be directly loaded into it for purification.The straight-through SPE column adopts a stepped design,which does not require a large sample volume and is suitable for the pretreatment of precious biological samples such as serum.The serum sample size adopted in this study was only 50 μL,which is much lower than that re-quired by other extraction methods.The straight-through SPE column can be used in conjunc-tion with a 96-well plate,and the purification treatment of 96 serum samples can be completed within 30 min with high efficiency. The mass spectrometry parameters were optimized,and the results indicated that the electro-spray ionization source temperature had a significant impact on the PFASs with later elution peaks.The effects of ion-source temperatures of 400 and 500℃on the peak shapes and re-sponse values of the target compounds were compared,and 400℃was selected.The sample pretreatment and ultra-high performance liquid chromatographic conditions were optimized.Briefly,50 μL of the sample was loaded into the SPE column and extracted twice using 200 μL of acetonitrile each time.The purified solution was collected,blown with nitrogen at 40℃to near dryness,dissolved in a 50% methanol aqueous solution,and then separated on a Poroshell 120 EC-C18 chromatographic column(100 mm×3 mm,2.7 μm)with 5 mmol/L ammonium ac-etate aqueous solution and methanol as mobile phases.Detection was conducted in multiple-re-action monitoring mode,and quantification was performed using an isotope internal standard method.The 17 detected PFASs had good linear relationships within the corresponding mass concentration ranges(r2>0.995),with limits of detection ranging from 3.6 ng/L to 14 ng/L and limits of quantification ranging from 11 ng/L to 42 ng/L.The recoveries in spiked serum samples were 89.3%-110.2%,the intra-day RSDs were 2.5%-9.8%,and the inter-day RSDs were 3.6%-10.2% .The method was applied to the detection of 20 human serum samples,and all 17 compounds were successfully detected.The proposed method is easy to operate,highly sensitive,has a small sample size and high detection efficiency,and is suitable for the large-scale monitoring and exposure assessment of PFASs in human serum samples.

关键词

固相萃取/超高效液相色谱-串联质谱法/全氟/多氟烷基化合物/血清

Key words

solid-phase extraction(SPE)/ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)/perfluorinated/polyfluoroalkyl compounds(PFASs)/serum

分类

化学

引用本文复制引用

林强,王健,李晶晶,苏东霞,李美丽,王佳,牛宇敏,邵兵..高通量固相萃取-超高效液相色谱-串联质谱法测定血清中17种全氟/多氟烷基化合物[J].色谱,2025,43(3):252-260,9.

基金项目

北京市科技计划课题(Z221100007122002) (Z221100007122002)

首都卫生发展科研专项(首发 2022-2G-3016).Beijing Science and Technology Program(No.Z221100007122002) (首发 2022-2G-3016)

Capital Health Development Research Project(No.2022-2G-3016) (No.2022-2G-3016)