Abstract
In compliance with national standards and inspection regulations for elevator machine room environments,a machine room environment detection system was developed.This system is capable of continuously monitoring critical parameters such as temperature,humidity,voltage,noise,and flame smoke within the machine room.The voltage data is acquired using the CR3X three-phase alternating current parameter module,while the noise levels of the computer room host are captured by the SN-ZS-BZ onboard noise module.Temperature and humidity readings are obtained through the DS18B20 module.For visual detection of flame and smoke,the K210 visual recognition module is used,and it incorporates an enhanced YOLOv8 algorithm for improved accuracy in visual recognition tasks.The gathered data is transmitted to a single-chip microcontroller-based control system for processing.Subsequently,the processed information is relayed to a remote monitoring system via the wireless communication EC800M-CN module.It is verified that the system maintains high detection accuracy for temperature,humidity,noise,and voltage measurements.The enhanced algorithm achieves an mAP0.5 of 83.2%and an mAP0.5:0.95 of 51.2%,representing improvements of 2.8%and 2.7%over the original algorithm,respectively.These results substantiate the effectiveness of the monitoring system.关键词