Due to the complex influencing factors of design flood in small watersheds and the lack of measured flood data,the accuracy of design flood results is difficult to grasp.Taking Guigang Pumped Storage Power Station in Guangxi as an example,this paper studies the determination method of design flood,analyzes and adopts various applicable methods to calculate the design flood,and determines the design flood results after comprehensive analysis.The results show that it is more reasonable and safer to use the reasoning formula method to calculate the design flood for power stations with small basin area,large slope and single underlying surface conditions.The research results can provide reference for the analysis and calculation of design flood in similar small watersheds.关键词
设计洪水/计算/小流域/贵港抽水蓄能电站Key words
design flood/calculation/small watershed/Guigang Pumped Storage Power Station分类
水利科学引用本文复制引用