锥形束CT中简单动态滤波策略的数值验证

王鹤然 谢吉雄 朱炯滔 张欣 谭雨航 苏婷 葛永帅

集成技术2025,Vol.14Issue(2):71-85,15.
集成技术2025,Vol.14Issue(2):71-85,15.DOI:10.12146/j.issn.2095-3135.20241021001

锥形束CT中简单动态滤波策略的数值验证

Numerical Validation of A Simple Dynamic Beam Filtration Strategy in Cone Beam CT

王鹤然 1谢吉雄 2朱炯滔 3张欣 1谭雨航 3苏婷 3葛永帅4

作者信息

  • 1. 中国科学院深圳先进技术研究院 深圳 518055||中国科学院大学 北京 100049||中国科学院深圳先进技术研究院先进探测材料与医学成像器件研究中心 深圳 518055
  • 2. 中国科学院深圳先进技术研究院先进探测材料与医学成像器件研究中心 深圳 518055
  • 3. 中国科学院深圳先进技术研究院 深圳 518055||中国科学院深圳先进技术研究院先进探测材料与医学成像器件研究中心 深圳 518055
  • 4. 中国科学院深圳先进技术研究院 深圳 518055||中国科学院大学 北京 100049||中国科学院深圳先进技术研究院先进探测材料与医学成像器件研究中心 深圳 518055||中国科学院深圳先进技术研究院劳特伯生物医学成像研究中心 深圳 518055||中国科学院医学成像科学与技术系统重点实验室 深圳 518055
  • 折叠

摘要

Abstract

For cone beam computed tomography(CBCT),there has long been a desire to modulate the intensity and distribution of the X-rays to accommodate the patient's anatomy as the gantry rotates from one projection to another.This would reduce both image artifacts and radiation dose.However,the current beam modulation setups,such as dynamic bowtie filters,may be too complex for practical use in clinical applications.This study aimed to investigate a simplified dynamic beam filtration strategy for CBCT imaging to reduce image artifacts and radiation dose.In this study,the beam filtration was designed to vary dynamically as the CBCT gantry rotates around the object.Specifically,two distinct components were integrated:the sheet filter part and the bowtie filter part.The dynamic beam filtration setup has two working schemes,one is a combination of dynamic sheet filter and dynamic bowtie filter,denoted as dynamic filter-dynamic bowtie(DFDB);the other is a combination of dynamic sheet filter and static bowtie filter,denoted as dynamic filter-static bowtie(DFSB).Numerical imaging experiments were performed for three human body parts:the shoulder,chest,and knee.In addition,the Monte Carlo simulation platform MC-GPU was used to generate the dose distribution maps.Results showed that the proposed DFDB and DFSB beam filtration schemes can significantly reduce the image artifacts and thus improve the CBCT image quality.Depending on the scanned object,the total radiation dose could be reduced by 30%.The proposed simple dynamic beam filtration strategy,especially the DFSB approach,could be beneficial in the future to improve the CBCT image quality with reduced image artifacts and radiation dose.

关键词

动态滤波/辐射剂量降低/硬化伪影减少/锥束CT

Key words

dynamic filtration/radiation dose reduction/artifacts reduction/cone beam computed tomography

分类

医药卫生

引用本文复制引用

王鹤然,谢吉雄,朱炯滔,张欣,谭雨航,苏婷,葛永帅..锥形束CT中简单动态滤波策略的数值验证[J].集成技术,2025,14(2):71-85,15.

基金项目

国家自然科学基金项目(12305349,12235006,12027812) (12305349,12235006,12027812)

深圳市科技计划项目(JSGGKQTD20210831174329010) (JSGGKQTD20210831174329010)

广东省基础与应用基础研究基金项目((2021TQ06Y108) This work was supported in part by National Natural Science Foundation of China(12305349,12235006,12027812),Shenzhen Science and Technology Program(JSGGKQTD20210831174329010),Guangdong Basic and Applied Basic Research Foundation(2021TQ06Y108) ((2021TQ06Y108)

集成技术

2095-3135

访问量0
|
下载量0
段落导航相关论文