某试制车型的不锈钢拉杆,在装配完成静置24h后发生了断裂失效,断裂位置在不锈钢拉杆的焊接接头处.通过宏观观察、扫描电镜分析、化学成分分析、金相与硬度检测等方法对不锈钢拉杆的失效原因进行了分析.结果表明:不锈钢拉杆的失效模式为氢脆断裂,拉杆材料中碳含量过高、焊接过程中在焊缝与热影响区出现马氏体组织,是导致氢脆断裂的根本原因.
The stainless-steel tie rod of a trial-produced vehicle model fractured after being left stationary for 24 hours after assembly.The fracture occurred at the welded joint of the stainless-steel tie rod.The failure causes of the stainless-steel tie rod were analyzed through methods such as macroscopic observation,scanning electron microscopy analysis,chemical composition analysis,metallographic and hardness testing.The results show that the failure mode of the…查看全部>>