强激光与粒子束2025,Vol.37Issue(3):134-138,5.DOI:10.11884/HPLPB202537.240267
无源积分器的参数测量
Parameter measurement of passive integrator
摘要
Abstract
To obtain the actual bandwidth and RC time constant of the passive integrator,the frequency characteristics of the integrator under 1 MΩ load are measured by using an active high impedance probe and a network analyzer.The simulation results show that the low frequency inflection point of integrator with 1 MΩ load is much lower than that of integrator with 50 Ω load,and the measured results are consistent with the simulation results.The measured results show that the high frequency band of the integrator frequency characteristic deviates from the theoretical trend of linear attenuation inversely proportional to the frequency,which is related to the spurious parameters of the actual circuit.The upper frequency limit of the integrator is determined by transforming the ordinate,and the working bandwidth of the integrator can be obtained by combining the calculated low frequency results.The RC constant is calculated by using the amplitude-frequency characteristic formula of integrator combined with the frequency sweep measurement results,which is simple and has less uncertainty.关键词
无源积分器/脉冲高电压/测量/频率响应/标定Key words
passive integrator/high voltage pulse/measurement/frequency response/calibration分类
信息技术与安全科学引用本文复制引用
卫兵,张元军,康军军,郭帆,徐乐..无源积分器的参数测量[J].强激光与粒子束,2025,37(3):134-138,5.基金项目
国家自然科学基金项目(12475157) (12475157)