| 注册
首页|期刊导航|中国骨伤|网格定位器在髋关节镜治疗股骨髋臼撞击征中的应用

网格定位器在髋关节镜治疗股骨髋臼撞击征中的应用

夏坤阳 阮文礼 王守赟 杨津先

中国骨伤2025,Vol.38Issue(2):176-182,7.
中国骨伤2025,Vol.38Issue(2):176-182,7.DOI:10.12200/j.issn.1003-0034.20230523

网格定位器在髋关节镜治疗股骨髋臼撞击征中的应用

Application of grid locator in hip arthroscopy for the treatment of femoroacetabular impingement features

夏坤阳 1阮文礼 1王守赟 1杨津先1

作者信息

  • 1. 大连市第二人民医院关节与运动中心,辽宁 大连 116014
  • 折叠

摘要

Abstract

Objective To explore the application effect of grid locator in hip arthroscopy for the treatment of femoral ac-etabular impingement(FAI).Methods Total of 50 patients of FAI were treated by arthroscopic hip joint surgery for from Jan-uary 2020 to January 2021,and were divided into two groups according to intraoperative positioning methods.Among them,27 cases in the positioner group were treated by hip arthroscopy assisted by grid positioner including 10 males and 17 females with a mean age of(35.91±9.92)years old.In the non-locator group,23 cases were treated with hip arthroscopy by positioning puncture according to the operator's experience including 12 males and 11 females with a mean age of(36.01±11.03)years old.Intraoperative fluoroscopy times,puncture time,adjusted puncture times and operation time of two groups were compared.The α Angle and lateral central edge(LCE)angle of hip joint were measured and compared before and after operation.Four e-valuation indexes were recorded and compared,including pain visual analogue scale(V AS),hip Harris score,non-inflammato-ry hip joint score(NAHS),hip joint activities of daily living(HOS-ADL).Results All patients were followed up for 6 to 12 months with an average of(18.69±3.72)months.The α angle and LCE angle of hip joint at 1 month after operation were de-creased in both groups(P<0.05),but there was no significant difference between groups(P>0.05).VAS,hip Harris score,NAHS and HOS-ADL score after operation were higher than those before operation(P<0.05),but there was no statistical sig-nificance between groups(P>0.05).Intraoperative fluoroscopy times(6.04±1.13),puncture time(13.19±3.52)min,puncture adjustment times(4.59±1.55)and operation time(48.28±3.38)min in the positioner group were less(shorter)than those of(13.43±2.56),(22.39±2.93)min,(10.43±3.33),(62.25±5.73)min in the non-positioner group(P<0.05).No postoperative complications occurred in both groups,and the pain was significantly relieved.Conclusion The application of hip arthroscopy in the treatment of femoral acetabular impingement sign can obtain good postoperative results.Compared with the traditional positioning method,the grid locator can improve the accuracy of skin positioning point,shorten the puncture time,reduce the number of fluoroscopy,and improve the efficiency of surgical puncture.

关键词

网格定位器/股骨髋臼撞击征/髋关节镜/定位准确率

Key words

Grid locator/Femoroacetabular impingement/Hip arthroscopy/Positioning accuracy

分类

医药卫生

引用本文复制引用

夏坤阳,阮文礼,王守赟,杨津先..网格定位器在髋关节镜治疗股骨髋臼撞击征中的应用[J].中国骨伤,2025,38(2):176-182,7.

中国骨伤

1003-0034

访问量0
|
下载量0
段落导航相关论文