电力勘测设计Issue(3):31-37,7.DOI:10.13500/j.dlkcsj.issn1671-9913.2025.03.006
交直流接地极混压同塔线路电磁环境分析
Electromagnetic Environment Analysis of Multi-Voltage Transmission Line with AC,DC,and DC Grounding Electrodes
陈琳韬 1龚有军 1郭盛源1
作者信息
- 1. 中国能源建设集团广东省电力设计研究院有限公司,广东 广州 510663
- 折叠
摘要
Abstract
To provide a design basis for ultra-high voltage direct current,extra-high voltage alternating current,and DC grounding electrodes sharing the same tower,this study conducts simulation analysis on the electromagnetic environment of a hybrid voltage tower designed for a UHV project.The limiting values of various electromagnetic environment indicators for hybrid voltage same-tower transmission lines are determined.Calculations are performed on electric field intensity,ion current density,radio interference,and audible noise within the transmission corridor using the hybrid voltage same-tower reference model.Through controlled variable analysis,the impacts of four key factors on the electromagnetic environment are investigated:AC conductor arrangement,DC conductor polarity configuration,grounding electrode operation modes,and tower structural layout.Results demonstrate that the ground-level electromagnetic environment indicators of the reference tower model all meet specified limits,while the vertical spacing between conductors in hybrid voltage towers must satisfy insulation requirements.关键词
输电线路/电磁环境/合成电场强度/可听噪声/无线电干扰Key words
transmission line/electromagnetic environment/synthetic field strength/audible noise/radio interference分类
动力与电气工程引用本文复制引用
陈琳韬,龚有军,郭盛源..交直流接地极混压同塔线路电磁环境分析[J].电力勘测设计,2025,(3):31-37,7.