Abstract
Contralateral inhibition of otoacoustic emissions is a common auditory efferent nerve function test.This paper summarizes the literatures on contralateral inhibition of otoacoustic emissions,which is commonly used in clinical studies,with an analysis of the test principles and recent progress in clinical applications.Characteristics of several types of otoacoustic emissions used in contralateral suppression were compared to provide useful information for basic and clinical research on auditory efferent nerve functions.关键词
听觉传出神经/对侧抑制/畸变产物耳声发射/瞬态声诱发耳声发射/刺激频率耳声发射Key words
auditory efferent nerve/opposite suppression/distortion production otoacoustic emissions/transient evoked otoacoustic emissions/stimulus-frequency otoacoustic emissions引用本文复制引用
陈潇露,黄珊,李吉平,钱敏飞..不同耳声发射在听觉传出神经功能检测中的应用[J].中华耳科学杂志,2025,23(2):327-331,5.