Optimization study is conducted on the application of flow injection analysis in the detection of anionic surfactants in water.By analyzing the physicochemical properties of anionic surfactants,three optimization strategies for online solid-phase extraction,fluorescence detection,and ion chromatography were explored,which improved the sensitivity,anti-interference ability,and detection selectivity of the methods,respectively.The experimental results show that all optimization methods are effective,providing a reference for the rapid and accurate analysis of trace anionic surfactants in water quality.

关键词

阴离子表面活性剂/流动注射分析法/固相萃取/荧光检测

Key words

anionic surfactant/flow injection analysis/solid phase extraction/fluorescence detection