世界有色金属Issue(4):183-185,3.
离子选择电极法测定选矿废水中的氟化物
Determination of Fluoride in Mineral Processing Wastewater by Ion Selective Electrode Method
丁小芮1
作者信息
- 1. 云南华联锌铟股份有限公司,文山 马关 663700
- 折叠
摘要
Abstract
With the development of our company's mineral processing,we attach great importance to the discharge of mineral processing wastewater.In order to ensure the accuracy of fluoride content detection in mineral processing wastewater,we have studied and verified the method for determining fluoride.Fluoride is mainly present in water environments,and its detection is a routine monitoring content in water environments.Exploring accurate measurement methods for fluoride is particularly important.At present,the detection of fluoride in water mainly adopts two methods:GB7484-1987 and HJ84-2016.The ion selective electrode technology is suitable for detecting fluoride content in water due to its simple equipment,easy operation,speed,and high sensitivity.The national standard GB7484-1987 specifies that the standard method for fluoride ion detection is the ion selective electrode method.This article conducted a study and validation of the ion selective electrode method.Through the organization and analysis of experimental data,we found that this method can accurately detect the content of fluoride in mineral processing wastewater.关键词
选矿废水/离子选择电极法/氟化物Key words
mineral processing wastewater/Ion selective electrode method/fluoride分类
资源环境引用本文复制引用
丁小芮..离子选择电极法测定选矿废水中的氟化物[J].世界有色金属,2025,(4):183-185,3.