广西水利水电Issue(2):101-103,3.
百色水库灌区灌溉用水水温保障措施
Irrigation water temperature guarantee measures of Baise Reservoir irrigation zone
郑舒雯 1孔庆嫦 1唐铭1
作者信息
- 1. 广西水利电力勘测设计研究院有限责任公司,南宁 530023
- 折叠
摘要
Abstract
There exist water temperature stratification in Baise Reservoir.In order to avoid the use of low-tempera-ture water that may affect crop growth,taking Baise Reservoir Irrigation Zone Project as example,the proper water temperature for crop irrigation in the irrigation zone and water temperature distribution in the reservoir area were studied,based on which it was decided that irrigation water temperature guarantee measures should be taken.After comparison and selection of schemes,the recommended stratified water intake scheme is an intake tower accommo-dating a floating cylinder gate with adjustable orifice.This scheme can ensure the automatic intake of surface water in the reservoir area based on the reservoir water level,meeting the requirements of crops for irrigation water temper-ature.关键词
水库水温/水温分层/灌溉水温/分层取水/百色水库灌区Key words
reservoir water temperature/water temperature stratification/irrigation water temperature/stratified wa-ter intake/Baise Reservoir irrigation zone分类
建筑与水利引用本文复制引用