水电站机电技术2025,Vol.48Issue(4):5-7,67,4.DOI:10.13599/j.cnki.11-5130.2025.04.002
某电站灯泡贯流式机组低水头下振动区划分研究
Research on the division of vibration zones in bulb tubular turbine generator units under low water head conditions in a hydropower station
胡中华 1胡靖远 2龙熠 1张一帆 1胡慧敏 1罗宏伟1
作者信息
- 1. 国家电投集团江西峡江发电有限公司,江西 吉安 331401
- 2. 湖南五凌哈电能效科技有限公司,湖南 长沙 410007
- 折叠
摘要
Abstract
In a low-head run-of-river power station,flood season operations are frequently impacted by factors such as flood control level,reservoir flood control requirements,downstream pond backwater effects,and head loss caused by blockage of debris in front of the trash rack.Consequently,the units often operate below their rated head,leading to severe vibrations that can jeopardize the safety of fasteners and structural components.To ensure the safe operation of the units at the power station,an in-depth analysis of the operating stability at low head was conducted for Unit 5.Three characteristic heads were selected for on-site stability tests.The test data were analyzed to evaluate the unit's stability under low heads,identify vibration zones,and provide technical support for its low head operation.关键词
灯泡贯流式机组/稳定性/振动区Key words
bulb tubular turbine generator unit/stability/vibration zone分类
建筑与水利引用本文复制引用
胡中华,胡靖远,龙熠,张一帆,胡慧敏,罗宏伟..某电站灯泡贯流式机组低水头下振动区划分研究[J].水电站机电技术,2025,48(4):5-7,67,4.