Abstract
Pumped storage power stations are often developed in the form of underground powerhouses,and the fire water supply source is generally taken from the public water supply main of the entire plant,which takes water from the lower reservoir.Some power stations have significant changes in the water level of the lower reservoir,and when the water level in the reservoir is at the dead water level,it cannot meet the fire water supply requirements for the most unfavorable point of the plant.Conventional high-pressure water supply systems cannot meet the needs of such power stations.Taking a certain power station as an example,this paper introduces the design scheme of the fire water supply system for a low head and high amplitude pumped storage power station,analyzes the advantages and disadvantages of various schemes,and summarizes the key points of linkage control for the fire water supply system.关键词
低水头/消防供水/高变幅/设计/抽水蓄能Key words
low water head/fire water supply/high amplitude/design/pumped storage分类