基于电流和电压联合制动的线路差动保护新原理

郭雅蓉 周泽昕 刘宇 王兴国 戴飞扬 徐凯

中国电机工程学报2025,Vol.45Issue(8):2899-2910,中插4,13.
中国电机工程学报2025,Vol.45Issue(8):2899-2910,中插4,13.DOI:10.13334/j.0258-8013.pcsee.232465

基于电流和电压联合制动的线路差动保护新原理

New Principle of Line Differential Protection Based on Combined Current and Voltage Restraint Principle

郭雅蓉 1周泽昕 2刘宇 3王兴国 2戴飞扬 2徐凯3

作者信息

  • 1. 华北电力大学,北京市 昌平区 102206
  • 2. 中国电力科学研究院有限公司,北京市 海淀区 100192
  • 3. 国家电网有限公司,北京市 西城区 100031
  • 折叠

摘要

Abstract

Aiming at the new energy power supply control characteristics lead to the new energy transmission line fault after the crossing current increases,resulting in the existing current differential protection of the differential current decreases,restraint current increases,the protection sensitivity decreases,increasing the risk of protection refusal.This paper presents a new principle of differential protection utilizing combined current and voltage restraint principle.In the current restraint dimension,the complex plane of current differential protection is established,which breaks away from the constraint of Kirchhoff’s current law on the threshold value of current differential protection.Based on the complex plane reflecting the current phase relationship on both sides of the line,the operating characteristics of current restraint principle are constructed to solve the problem of protection maloperation caused by the unbalanced current outside the area.In the voltage restraint dimension,the line conductance characteristic complex plane is established to reduce the dependence of the compensation capacitor current on the line parameters,eliminate the influence of the crossing current on the protection sensitivity during the fault in the zone.Voltage correction technology and high voltage low cosine value blocking technology are proposed to solve the problem of low voltage dead zone and high voltage sensitivity.Finally,a new principle of current differential protection is established based on the combined restraint principle of current and voltage.Simulation results show that the protection principle can still operate reliably when the fault current of the new energy transmission line is only 500 A,doubling the sensitivity compared with the existing protection,and providing high reliability in case of out-of-area faults.Solve the problem that the existing current differential protection sensitivity is seriously insufficient due to the increase of fault ride-through current of new energy transmission line,and create conditions for large-scale new energy consumption.

关键词

差动保护/电流制动/电压制动/联合制动/新能源送出线路

Key words

differential protection/current restraint/voltage restraint/combined restraint principle/new energy transmission lines

分类

动力与电气工程

引用本文复制引用

郭雅蓉,周泽昕,刘宇,王兴国,戴飞扬,徐凯..基于电流和电压联合制动的线路差动保护新原理[J].中国电机工程学报,2025,45(8):2899-2910,中插4,13.