| 注册
首页|期刊导航|建筑钢结构进展|方钢管混凝土柱全螺栓装配式连接节点抗震性能数值分析

方钢管混凝土柱全螺栓装配式连接节点抗震性能数值分析

林晓俊 张爱林 张艳霞 沈森

建筑钢结构进展2025,Vol.27Issue(4):56-68,13.
建筑钢结构进展2025,Vol.27Issue(4):56-68,13.DOI:10.13969/j.jzgjgjz.20231020001

方钢管混凝土柱全螺栓装配式连接节点抗震性能数值分析

Numerical Analysis of Seismic Performance of Fully Bolted Prefabricated CFSST Column Connection Joints

林晓俊 1张爱林 2张艳霞 2沈森1

作者信息

  • 1. 北京建筑大学 土木与交通工程学院,北京 100044
  • 2. 北京建筑大学 土木与交通工程学院,北京 100044||北京建筑大学 北京节能减排与城乡可持续发展省部共建协同创新中心,北京 102627||北京建筑大学 工程结构与新材料北京市高校工程研究中心,北京 100044
  • 折叠

摘要

Abstract

In order to solve the problems of serious pollution and low construction efficiency caused by on-site welding of concrete-filled steel tubular column-column connection joints,and to integrate the advantages of cross-shaped core tubes for convenient processing and construction,a new type of connection joint is proposed.This joint is a fully bolted assembly connection joint with built-in cross-shaped core tube for concrete-filled square steel tubular(CFSST)columns,based on the self-tapping bolt and core tube column joint proposed by the research group.Based on the proposed static test results of this connection joint,a numerical analysis model is established using ABAQUS software to verify the reliability of the simulation method,and a parametric analysis is carried out for the different combinations of self-tapping bolts,stiffening ribs and cross-shaped core tube.The results show that the numerical analysis results are in good agreement with the test results,which verifies the reliability of the numerical analysis method.The self-tapping bolts effectively inhibit the buckling deformation and relative opening of the flange plate,which increases the joint bending capacity by 19.94%on average,and slows down the stiffness degradation of the joint.The stiffening ribs inhibit the deformation of the flange plate,which increases the joint bending capacity by 3.70%on average,but increases the possibility of relative opening.The cross-shaped core tubes effectively inhibit the buckling deformation of the flange plate and the local buckling of the column wall,increasing the bearing capacity and stiffness,and delaying the stiffness degradation of the joint.Overall,the stiffening ribs have little effect on the bending capacity of the joint,and increase the relative openings of the upper and lower flange plates.Therefore,the fully bolted assembly joint for CFSST columns can be optimized as a combination of core tube and self-tapping bolts,and the cross-shaped core tube,self-tapping bolts and concrete have a good mechanism of synergy.Both the joints before and after the optimization can achieve the performance design goal of"strong joints,weak members",which are recommended in the engineering application.

关键词

十字形芯筒/方钢管混凝土柱/自攻螺栓/抗震性能/数值分析

Key words

cross-shaped core tube/concrete-filled square steel tubular(CFSST)column/self-tapping bolt/seismic performance/numerical analysis

分类

土木建筑

引用本文复制引用

林晓俊,张爱林,张艳霞,沈森..方钢管混凝土柱全螺栓装配式连接节点抗震性能数值分析[J].建筑钢结构进展,2025,27(4):56-68,13.

基金项目

国家自然科学基金(51778036),北京市教委科研计划(KZ201910016018),长江学者和创新团队发展计划(IRT_17R06) (51778036)

建筑钢结构进展

OA北大核心

1671-9379

访问量0
|
下载量0
段落导航相关论文