| 注册
首页|期刊导航|铁路通信信号工程技术|SC350型道岔电务维护典型问题分析探讨

SC350型道岔电务维护典型问题分析探讨

张重

铁路通信信号工程技术2025,Vol.22Issue(4):117-121,5.
铁路通信信号工程技术2025,Vol.22Issue(4):117-121,5.DOI:10.3969/j.issn.1673-4440.2025.04.018

SC350型道岔电务维护典型问题分析探讨

Analysis and Exploration of Typical Problems in Electrical Maintenance of SC350 Switches

张重1

作者信息

  • 1. 中国铁路济南局集团有限公司电务部,济南 250031
  • 折叠

摘要

Abstract

SC350 switches are difficult to maintain and have a high failure rate due to factors such as complex structure,densely located connection parts,and difficult adjustment.This paper analyzes and discusses the typical problems encountered during the maintenance of this type of switches,such as the high rebound force of the switch rail,switch gap,asynchronous switch point closure,and improper closure of the point frog.Based on on-site maintenance practices,measures are proposed mainly from the perspective of electrical maintenance,including distinguishing the source of the rebound force of the switch rail,relieving the stress on the frames,standardizing the adjustment of the throw of switch,and inspecting the relative state of the point frog,in order to reduce the failures of this type of switches.Through practical application of the aforementioned methods and measures,the failure rate of the SC350 switches has been significantly reduced.These analyses and maintenance suggestions are of great significance for enhancing the reliability and safety of the application of the SC350 switches.

关键词

SC350型/复式交分道岔/外锁闭转换设备/典型问题/电务维护

Key words

SC350/double slip switches/external locking switching device/typical problem/electrical maintenance

分类

交通工程

引用本文复制引用

张重..SC350型道岔电务维护典型问题分析探讨[J].铁路通信信号工程技术,2025,22(4):117-121,5.

铁路通信信号工程技术

1673-4440

访问量6
|
下载量0
段落导航相关论文