| 注册
首页|期刊导航|储能科学与技术|不同冷却工质对电池热失控抑制的效果

不同冷却工质对电池热失控抑制的效果

范文强 史梓男 杨代铭 梁惠施 陈烨

储能科学与技术2025,Vol.14Issue(4):1554-1563,10.
储能科学与技术2025,Vol.14Issue(4):1554-1563,10.DOI:10.19799/j.cnki.2095-4239.2024.0975

不同冷却工质对电池热失控抑制的效果

Experimental study on the suppression effect of different coolants on battery thermal runaway

范文强 1史梓男 2杨代铭 2梁惠施 2陈烨3

作者信息

  • 1. 清华大学深圳国际研究生院,广东 深圳 518055
  • 2. 清华四川能源互联网研究院,四川 成都 610213
  • 3. 珠海沃顿智能信息技术有限公司,广东 珠海 519085
  • 折叠

摘要

Abstract

The choice of coolants is particularly crucial,and immersion cooling systems offer outstanding advantages in thermal management technology,with high potential and application value.To investigate the actual performance of different coolants and their effectiveness in suppressing battery thermal runaway,this study conducted thermal runaway experiments on 86 Ah lithium iron phosphate cells immersed in six coolants:thermal oil(L-QD350),10#transformer oil,vegetable oil(DS3 natural ester),silicone oil(50 cSt),ethylene glycol stock solution(99.9%,polyester grade),and electronic fluoride liquid(Novec-7200).The performance of these coolants was compared based on experimental phenomena,voltage and temperature curves,time-domain and thermal evaluation indicators of each link,and the influence of vegetable oil immersion level on thermal runaway suppression.The experimental results demonstrate that all coolants produced significant white smoke during the thermal runaway process.However,white smoke ceased after prolonged immersion in vegetable oil,whereas thermal oil and electronic fluoride liquid exhibited spontaneous ignition during thermal runaway.Vegetable oil and ethylene glycol stock solutions performed well in various time-domain and thermal evaluation indicators,whereas silicone oil performed poorly in time-domain indicators,and electronic fluoride liquid performed poorly in thermal indicators.In summary,vegetable oil and ethylene glycol stock solutions outperformed the other coolants in terms of cooling efficiency and thermal runaway suppression,whereas silicone oil and electronic fluoride liquid exhibited relatively weaker performance.In addition,the amount of vegetable oil added has a significant impact on thermal runaway.The higher the immersion amount,the slower the development of thermal runaway,and the lower the temperature on the battery surface,the less severe the thermal runaway.However,the optimal amount of coolants should be determined based on the application conditions,cost,and specific coolant parameters.These findings provide effective data support for battery thermal management systems and provide a reference for selecting coolants for immersion cooling systems.

关键词

热失控/冷却工质/热管理/泄压阀/浸没式冷却

Key words

thermal runaway/coolants/thermal management/pressure relief valve/immersion cooling

分类

信息技术与安全科学

引用本文复制引用

范文强,史梓男,杨代铭,梁惠施,陈烨..不同冷却工质对电池热失控抑制的效果[J].储能科学与技术,2025,14(4):1554-1563,10.