摘要

Abstract

The valve hall of the converter station is the core area of the direct current equipment.The fireproof performance of the valve hall blockage plays an important role in supporting the daily operation of the direct current transmission system.This paper analyzed the fire protection capability of the plugging structure of the high-end valve hall in±1 100 kV UHV converter station.This paper determined the fire hazard source according to the material and working mechanism of the blocking structure of the±1 100 kV high-level valve hall.This paper established a blocking physical simulation model of the±1 100 kV valve hall,and simplified it according to the blocking structure components.The t2 fire source model was used to describe the heat release rate of the fire hazard source.The temperature variation trend and the fire spread of the valve side casing when the valve side was on fire were calculated through the visual operation software PyroSim.The simulation results show that the fire spread is limited to the valve side casing area,indicating that the high-end valve hall plugging structure can inhibit the spread of the fire,which provides key basis for designing a reasonable fire extinguishing plan.

关键词

±1 100 kV特高压换流站/阀厅仿真/封堵结构/阀侧套管

Key words

±1 100 kV UHV converter station/Valve hall simulation/Blocking structure/Valve side casing

分类

信息技术与安全科学

引用本文复制引用

刘磊,张陵..特高压换流站高端阀厅封堵火灾仿真与分析[J].计算机应用与软件,2025,42(4):381-388,8.

基金项目

国家电网公司科技项目(SGXJDK00PJJS2000062). (SGXJDK00PJJS2000062)

计算机应用与软件

OA北大核心

1000-386X

访问量0
|
下载量0
段落导航相关论文