家电科技2025,Vol.1Issue(1):116-120,5.DOI:10.19784/j.cnki.issn1672-0172.2025.01.019
基于空气焓值法测量空调器制冷量的不确定度分析
Uncertainty analysis of air conditioning cooling capacity measurement based on air-enthalpy test method
张子祺 1刘杰 2杨双 1张宇佳 1徐传芳 2梅飞强 3王伯燕1
作者信息
- 1. 中家院(北京)检测认证有限公司 北京 100176
- 2. 安徽中认倍佳科技有限公司 安徽 滁州 239000
- 3. 苏州UL美华认证有限公司 江苏 苏州 215122
- 折叠
摘要
Abstract
Taking the air enthalpy method as an example to measure the rated cooling capacity of room air conditioners,this paper analyzes the calculation formulas for the air moisture content,saturated water vapor partial pressure,specific heat,and other thermal properties on the indoor supply and return sides,as well as the measurement model for the rated cooling capacity.By analyzing the measurement model of customized cooling capacity,the input of uncertainty was determined,and the uncertainty of customized cooling capacity is evaluated using GUM method and adaptive MCM method,respectively.After comparison and verification,the results obtained by the two methods are basically consistent.The adaptive MCM method can greatly simplify the calculation of partial derivatives and sensitivity coefficients for various uncertainty components in the uncertainty assessment process of rated cooling capacity,while also ensuring the calculation accuracy of rated cooling capacity uncertainty.关键词
房间空调器/不确定度/制冷量Key words
Room air conditioner/Uncertainty evaluation/Cooling capacity分类
信息技术与安全科学引用本文复制引用
张子祺,刘杰,杨双,张宇佳,徐传芳,梅飞强,王伯燕..基于空气焓值法测量空调器制冷量的不确定度分析[J].家电科技,2025,1(1):116-120,5.