人民长江2025,Vol.56Issue(4):200-205,6.DOI:10.16232/j.cnki.1001-4179.2025.04.027
新型装配式测压管设计原理及其工程应用
Design principle of new assembled pressure measuring pipe and its engineering application
摘要
Abstract
In order to solve the problem of easy blockage and difficult cleaning of pressure measuring pipes in water conservancy projects,a new type of assembled pressure measuring pipe with double-layer structure(composed of inner pipe and outer pipe,in which the inner pipe can be pulled out for cleaning or replacement during use)was designed.The diameter of the new pressure measuring pipe was optimized,and the influence of the pipe diameter on the lag time of the water level measuring of the pressure measuring pipe was discussed through theoretical analysis and mathematical derivation.Theoretical analysis showed that a small change in the inner diameter had a limited effect on the measuring lag time.It is recommended to increase the outer diameter to a-bout 100 mm for ease fabrication and installation.The engineering practice showed that the new assembled pressure measuring pipe can be successfully manufactured and installed by using the existing construction technology,and the pull-out design of the inner pipe was feasible.The research results can provide reference for seepage monitoring of water conservancy projects.关键词
水位监测/装配式测压管/渗压计/监测滞后时间Key words
water level measuring/assembled pressure measuring pipe/osmometer/measuring lag time分类
建筑与水利引用本文复制引用
赵津磊,李星,曹猛..新型装配式测压管设计原理及其工程应用[J].人民长江,2025,56(4):200-205,6.基金项目
国家自然科学基金青年基金项目(52209165) (52209165)