The fixed loss model or empirical formula model of transformer has been widely used in the line loss a-nalysis of power system.With the large-scale access of high proportion of new energy generation,the power flow in the power system has changed from one-way flow to two-way flow,and the operation state of the transformer has also changed.The traditional iron loss calculation model has certain limitations.Based on Jiles-Atherton ferromagnetic hysteresis model,a dynamic transformer iron loss calculation method is proposed.Through nonlinear core model-ing,the variation of transformer core loss under the condition of power reverse transmission is analyzed to improve the accuracy of core loss calculation.Pspice simulation test results and recording data show that the iron loss of transformer increases significantly under the condition of power reverse transmission,and the effectiveness and ac-curacy of the proposed method are also verified.关键词
新能源接入/铁损损耗/Jiles-Atherton铁磁磁滞模型/潮流倒送/非线性磁芯Key words
new energy access/iron loss/Jiles-Atherton ferromagnetic hysteresis model/power flow reverse trans-mission/nonlinear core分类
信息技术与安全科学引用本文复制引用
王奕沣,马喜平,岑炳成,朱丹丹,梁昊,姜彤..高比例新能源接入下的动态铁损模型分析方法[J].电测与仪表,2025,62(5):177-184,8.基金项目
国家电网公司科技项目(52272221N002) (52272221N002)