| 注册
首页|期刊导航|临床误诊误治|新型组合微创半髋置换术在Evans分型Ⅲ、Ⅳ型老年股骨粗隆骨折中应用效果

新型组合微创半髋置换术在Evans分型Ⅲ、Ⅳ型老年股骨粗隆骨折中应用效果

李印鹏 王寅 郝明 曹斌 李熙明 吴涛

临床误诊误治2025,Vol.38Issue(10):66-72,7.
临床误诊误治2025,Vol.38Issue(10):66-72,7.DOI:10.3969/j.issn.1002-3429.2025.10.011

新型组合微创半髋置换术在Evans分型Ⅲ、Ⅳ型老年股骨粗隆骨折中应用效果

Application Effect of New Combined Minimally Invasive Hemiarthroplasty in Elderly Patients with Trochanteric Femoral Fractures of Evans Types Ⅲ and Ⅳ

李印鹏 1王寅 1郝明 1曹斌 1李熙明 1吴涛2

作者信息

  • 1. 050000 石家庄,石家庄市人民医院创伤科
  • 2. 050000 石家庄,石家庄市人民医院骨科
  • 折叠

摘要

Abstract

Objective To explore the effect of the new combined minimally invasive hemiarthroplasty in the treatment of trochanteric femoral fractures of Evans type Ⅲ and Ⅳ in elderly patients.Methods A total of 103 elderly patients with trochanteric femoral fractures of Evans type Ⅲ and Ⅳ from January 2019 to October 2022 were selected and categorized into a minimally invasive group(n=35),an internal fixation group(n=34),and a replacement group(n=34)based on different surgical procedures.These groups underwent novel combined minimally invasive hemiarthroplasty,proximal femoral nail an-tirotation(PFNA)fixation,and artificial hip replacement,respectively.Perioperative indicators,complications,and excel-lent and good rates of hip joint function were statistically analyzed for the three groups,as well as the thromboelastographic pa-rameters,gait parameters,and Berg Balance Scale(BBS)scores before and after surgery.Results The minimally invasive group and internal fixation group had less intraoperative blood loss,shorter duration of operation,time to ambulation,and length of hospital stay than the replacement group(P<0.01).The postoperative drainage volume in the minimally invasive group was less than that in the replacement group(P<0.05).There was no significant difference in perioperative indicators between the minimally invasive group and the internal fixation group(P>0.05).At 3 d after surgery,the thromboelasto-graphic parameters,including the α angle,K value,and MA value,in the minimally invasive group and internal fixation group were lower than those in the replacement group,while the R value was higher than that in the replacement group(P<0.05).There was no significant difference in thromboelastographic parameters between the minimally invasive group and the internal fixation group at 3 d after surgery(P>0.05).At 6 months after surgery,the walking speed,stance phase,stride length,and BBS score in the minimally invasive group and internal fixation group were superior to those in the replacement group,and superior in the minimally invasive group than in the internal fixation group(P<0.05).There was no significant difference in the overall incidence of complications and the excellent and good rate of hip joint function among the three groups(P>0.05).Conclusion The new combined minimally invasive hemiarthroplasty is effective in improving walking and bal-ance functions in elderly patients with trochanteric femoral fractures of Evans types Ⅲ and Ⅳ,which has minimal impact on coagulation function and high safety.

关键词

股骨粗隆骨折/老年人/Evans分型/半髋置换术/血栓弹力图/步态/Berg平衡量表/并发症

Key words

Trochanteric femoral fracture/Elderly/Evans types/Hemiarthroplasty/Thrombelastography/Gait/Berg balance scale/Complications

分类

医药卫生

引用本文复制引用

李印鹏,王寅,郝明,曹斌,李熙明,吴涛..新型组合微创半髋置换术在Evans分型Ⅲ、Ⅳ型老年股骨粗隆骨折中应用效果[J].临床误诊误治,2025,38(10):66-72,7.

基金项目

2019年度河北省医学科学研究重点课题计划(20191465) (20191465)

石家庄市科技计划项目(231460573) (231460573)

临床误诊误治

1002-3429

访问量0
|
下载量0
段落导航相关论文