| 注册
首页|期刊导航|色谱|超高效液相色谱-串联质谱同时测定尿液中10种邻苯二甲酸酯代谢物

超高效液相色谱-串联质谱同时测定尿液中10种邻苯二甲酸酯代谢物

赵小英 康慧 王燕燕 李文慧 陈铭 可婵 秦峰 康熙雄

色谱2025,Vol.43Issue(6):640-649,10.
色谱2025,Vol.43Issue(6):640-649,10.DOI:10.3724/SP.J.1123.2024.04002

超高效液相色谱-串联质谱同时测定尿液中10种邻苯二甲酸酯代谢物

Simultaneous determination of 10 phthalate metabolites in urine by ultra performance liquid chromatography-tandem mass spectrometry

赵小英 1康慧 2王燕燕 1李文慧 3陈铭 3可婵 1秦峰 1康熙雄2

作者信息

  • 1. 沈阳药科大学分析化学实验室,辽宁 沈阳 110000
  • 2. 北京中检体外诊断工程技术研究中心,北京 100095
  • 3. 裕菁科技(上海)有限公司,上海 200120
  • 折叠

摘要

Abstract

Phthalates(PAEs)are widely employed as plasticizers in plastic products that are used in industrial,agricultural,food,medical,and other fields.PAEs are relatively weakly bonded to plastic products through non-covalent interactions.Consequently,PAEs can easily leak from the product into the environment,which exposes the public to PAEs through food intake,skin absorption from personal care products,and by inhaling air.Related studies have shown that PAEs are endocrine-disrupting substances and that long-term exposure to PAEs may result in diseases of the nervous,reproductive,cardiovascular and immune systems.In addition,excessive exposure to PAEs may trigger inflammatory responses and induce tumors.Therefore,establishing a highly sensitive assay for determining PAE levels in the human body following exposure is an important objective.PAEs generally have half-lives of less than 24 h;they are rapidly metabolized through enzymatic hydrolysis after entering the human body and excreted through urine.Therefore,most studies have focused on PAE metabolites as target compounds;hence,human body exposure to PAEs can be assessed by analyzing the types and levels of these metabolites.Herein,we established a method for simultaneously determining ten phthalate(PAE)metabolites in human urine using ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The ten PAE metabolites in urine were separated using an ACQUITY UPLC BEH Phenyl column(50 mm×2.1 mm,1.7 μm).Gradient elution was performed using 0.1%formic acid aqueous solution and 0.1%formic acid in acetonitrile as the mobile phases,at a flow rate of 0.5 mL/min,a column temperature of 40℃,and a sample size of 20 μL.Data were acquired in negative-ion electrospray ionization(ESI)and multiple reaction monitoring(MRM)modes,and quantified using the isotope internal standard method.The method was found to be highly specific,with the ten PAE metabolites exhibiting good linearities in their linear ranges,with limits of detection(LODs)and quantification(LOQs)of 0.03-0.3 and 0.1-1 ng/mL,respectively.Under the four quality control(QC)levels,the intra-day and inter-day precisions of the ten PAE metabolites were all≤8.3%,and the accuracy ranged from-10.5%to 7.3%.The method was used to assess the exposure levels of PAE metabolites in the urine samples of 60 volunteers,with 1-6 kinds of PAE metabolites detected in the urine of each volunteer.This method is sensitive,accurate,simple,efficient,and suitable for the large-scale biological monitoring of PAE metabolites.

关键词

超高效液相色谱-串联质谱/邻苯二甲酸酯代谢物/尿液样品/塑化剂

Key words

ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)/phthalate metabolites/urine samples/plasticizer

分类

化学

引用本文复制引用

赵小英,康慧,王燕燕,李文慧,陈铭,可婵,秦峰,康熙雄..超高效液相色谱-串联质谱同时测定尿液中10种邻苯二甲酸酯代谢物[J].色谱,2025,43(6):640-649,10.

基金项目

国家重点研发计划(2022YFC2009600,2022YFC2009603). National Key Research and Development Program of China(Nos.2022YFC2009600,2022YFC2009603). (2022YFC2009600,2022YFC2009603)

色谱

OA北大核心

1000-8713

访问量0
|
下载量0
段落导航相关论文