| 注册
首页|期刊导航|原子能科学技术|氦氙气冷空间堆耦合布雷顿循环核电源系统瞬态特性分析

氦氙气冷空间堆耦合布雷顿循环核电源系统瞬态特性分析

吴杨茂 唐思邈 朱隆祥 连强 张卢腾 马在勇 孙皖 潘良明

原子能科学技术2025,Vol.59Issue(5):973-987,15.
原子能科学技术2025,Vol.59Issue(5):973-987,15.DOI:10.7538/yzk.2024.youxian.0951

氦氙气冷空间堆耦合布雷顿循环核电源系统瞬态特性分析

Transient Characteristics Analysis of He-Xe Cooled Space Reactor Coupled with Brayton Cycle Nuclear Power System

吴杨茂 1唐思邈 1朱隆祥 1连强 1张卢腾 1马在勇 1孙皖 1潘良明1

作者信息

  • 1. 重庆大学低品位能源利用技术及系统教育部重点实验室,重庆 400044||重庆大学核工程与核技术系,重庆 400044
  • 折叠

摘要

Abstract

Space nuclear power is crucial for future space missions,providing reliable energy for long-duration operations.Gas-cooled nuclear reactors,with high coolant outlet temperatures,are well-suited for integration with a closed Brayton cycle to achieve efficient megawatt-class power generation.A Megawatt-class Advanced Gas-cooled Nuclear System(MAGNUS)was developed featuring a high-temperature gas-cooled reactor coupled with a closed Brayton cycle in this study,establishing a comprehensive mathematical and physical model.The reactor model incorporates point reactor kinetics,reactivity feedback,coolant flow heat transfer,and thermal behavior of the fuel and structural materials.The Brayton cycle model includes key components such as the turbine-alternator-compressor(TAC),recuperator,and gas cooler.A robust numerical method was employed for solution,and a transient system analysis program was developed.The program's steady-state and transient results were validated,followed by transient analyses of key accident scenarios,including positive reactivity insertion accidents and TAC shaft speed reduction events.For a positive reactivity insertion below 0.152$,the reactor and Brayton cycle stabilizes naturally without requiring active control.Introducing positive reactivity enhances the system's thermal cycle efficiency.When a 0.1 $ reactivity insertion occurs,the reactor stabilizes at 3.67 MWt(117%of core rated thermal power),while thermal-to-electric conversion efficiency improves from 32.1%to 34.4%.Early activation of protective measures reduces the required negative reactivity compensation while maintaining high efficiency.In contrast,delayed intervention requires stronger negative reactivity,leading to a decrease in core temperature and a reduction in thermal efficiency.During TAC shaft speed reduction,reactor heat output remains proportional to system load.Within a safe operating range,adjusting shaft speed effectively improves efficiency by minimizing temperature differential losses.However,speed regulation is self-stabilizing only down to 80%of rated shaft speed.If the speed drops further,safety measures must be implemented to prevent coolant flow reduction,excessive reactor heating,and potential fuel cladding failure.

关键词

空间核电源/高温气冷快堆/闭式布雷顿循环/瞬态分析

Key words

space nuclear power/high-temperature gas-cooled fast reactor/closed Brayton cycle/tran-sient analysis

分类

能源科技

引用本文复制引用

吴杨茂,唐思邈,朱隆祥,连强,张卢腾,马在勇,孙皖,潘良明..氦氙气冷空间堆耦合布雷顿循环核电源系统瞬态特性分析[J].原子能科学技术,2025,59(5):973-987,15.

基金项目

中国博士后科学基金(2023M730397) (2023M730397)

重庆市自然科学基金(2023NSCQ-BHX0189) (2023NSCQ-BHX0189)

原子能科学技术

OA北大核心

1000-6931

访问量0
|
下载量0
段落导航相关论文