基于肌骨超声探讨电针居髎对中风偏瘫患者臀中肌及下肢运动功能的影响

吴维坤 杨冬岚 林子涵 陈嘉铭 黄丽萍 周文强

针刺研究2025,Vol.50Issue(5):592-598,7.
针刺研究2025,Vol.50Issue(5):592-598,7.DOI:10.13702/j.1000-0607.20240180

基于肌骨超声探讨电针居髎对中风偏瘫患者臀中肌及下肢运动功能的影响

Effects of electroacupuncture at Juliao(GB29)on the gluteus medius and lower limb motor function in patients with stroke-related hemiplegia

吴维坤 1杨冬岚 1林子涵 1陈嘉铭 2黄丽萍 3周文强1

作者信息

  • 1. 泉州市中医院针灸康复科,福建 泉州 362000
  • 2. 泉州市正骨医院软伤科,福建 泉州 362000
  • 3. 厦门大学附属龙岩市中医院康复科,福建 龙岩 361000
  • 折叠

摘要

Abstract

Objective To investigate the effects of electroacupuncture(EA)at Juliao(GB29)on lower limb motor function,balance function,and the gluteus medius contraction ratio and thickness in patients with stroke-related hemiplegia,as well as the correlation between the gluteus medius and lower limb motor function and balance function in these patients.Methods A total of 68 patients with stroke-related hemiplegia were randomly divided into an observation group(34 cases,with 1 dropped out and 1 withdrawal)and a control group(34 cases,with 2 dropped out).The control group received conventional acupuncture in addition to standard medical treatment for their underlying conditions,along with rehabilitation training.The observation group received EA at GB29 on the hemiplegic side for 30 min per session,once daily,5 times a week,over a total treatment duration of 4 weeks,based on the control group's treatment.Before treatment,the correlation between the contraction ratio of the gluteus medius and the scores of the lower limb Fugl-Meyer Assessment(FMA)and the Berg Balance Scale(BBS)was analyzed.The thickness of the gluteus medius was measured,and the contraction ratio was calculated before treatment and 4 weeks after treatment.Assessments of the lower limb FMA and BBS scores were conducted before treatment,and 2 and 4 weeks after treatment.Results Before treatment,the contraction ratio and thickness of the gluteus medius on the hemiplegic side were lower than those on the non-hemiplegic side in both groups(P<0.05).The gluteus medius contraction ratio before treatment demonstrated a positive correlation with the lower limb FMA and BBS scores(P<0.05).The gluteus medius contraction ratio and thickness on the hemiplegic side 4 weeks after treatment,as well as the lower limb FMA and BBS scores 2 and 4 weeks after treatment,were significantly higher than those before treatment in both groups(P<0.05).Furthermore,the observation group showed a greater contraction ratio of the gluteus medius,as well as higher FMA and BBS scores 4 weeks after treatment when compared with the control group(P<0.05).Conclusion The level of gluteus medius activation is positively correlated with lower limb motor function and balance function in patients with stroke-related hemiplegia.EA at the GB29 effectively activates the gluteus medius on the hemiplegic side,providing a stability mechanism for the lumbopelvic-hip complex,thereby improving lower limb motor function and balance in patients with stroke.

关键词

电针/居髎/臀中肌/肌骨超声/下肢运动功能

Key words

Electroacupuncture/Juliao(GB29)/Gluteus medius/Musculoskeletal ultrasound/Lower limb motor function

引用本文复制引用

吴维坤,杨冬岚,林子涵,陈嘉铭,黄丽萍,周文强..基于肌骨超声探讨电针居髎对中风偏瘫患者臀中肌及下肢运动功能的影响[J].针刺研究,2025,50(5):592-598,7.

基金项目

福建省中医药科研课题项目(No.2021zylc49) (No.2021zylc49)

针刺研究

OA北大核心

1000-0607

访问量0
|
下载量0
段落导航相关论文