This paper conducts a comprehensive analysis of the operational characteristics and causes of fluctuations in the triple-function system based on an air-source heat pump system in the Central Plains region,taking into account the climatic conditions of the region.By focusing on the experimental data obtained from four modes of operation:cooling,cooling and hot water production,heating,and hot water production alone,we explore the compressor's suction and discharge pressures,system superheat,and electronic expansion valve opening.The aim is to enhance the overall efficiency of the unit and ensure the safe operation of the system.The results indicate that in heating mode,the suction and discharge pressures of the system remain relatively stable,but the electronic expansion valve opening decreases and the superheat drops due to frosting.In cooling mode,the fluctuations in superheat and electronic expansion valve opening are stable.However,in both cooling and hot water production and hot water production alone modes,the reduction in liquid refrigerant in various circuits leads to an increase in superheat towards the end of the operation cycle.The discharge pressure continues to rise with the increase in water temperature,causing significant fluctuations in the electronic expansion valve opening.This high discharge pressure state is detrimental to the stable and safe operation of the system.

关键词

三联供空调系统/空气源热泵/运行特性/高效节能

Key words

Triple-function Air-conditioning System/Air-source Heat Pump/Operating Characteristics/High-efficiency Energy Saving

分类

建筑与水利

引用本文复制引用

刘雅楠,张栋梁,闫帅兵,杜金宇..基于空气源热泵的三联供空调系统运行特性分析[J].制冷,2025,44(2):21-26,6.

制冷

1005-9180

访问量0
|
下载量0
段落导航相关论文