电工技术学报2025,Vol.40Issue(10):3131-3142,12.DOI:10.19595/j.cnki.1000-6753.tces.240700
考虑VSI非线性影响的内置式永磁同步电机无电流传感器MTPA控制策略
Current Sensorless MTPA Operation of Interior Permanent Magnet Synchronous Motor Drives Considering VSI Nonlinearity
摘要
Abstract
The maximum torque per ampere(MTPA)control strategy can fully use the reluctance torque to output the maximum torque per unit stator current and improve the operating efficiency of interior permanent magnet synchronous motors(IPMSMs).Still,the traditional formula method or the high-frequency signal injection method requires the installation of at least two phase-current sensors to obtain the current information of the motor.Once the current sensor fails,the closed-loop control of the system will fail and cause unpredictable damage.The paper proposes an MTPA control strategy for IPMSM without current sensors.The strategy can accurately realize the MTPA control of the permanent magnet synchronous motor by calculating the optimal voltage control instruction only from the rotational speed information and the mathematical model of the system. Firstly,the relationship between the control voltage command and the rotational speed is calculated using the formula method according to the mathematical model of the IPMSM and the conditions of the MTPA control.Secondly,inverter nonlinearity can cause the inverter output voltage to deviate from the commanded voltage,resulting in the motor deviating from the MTPA operating point.Therefore,the mean value compensation method is proposed to compensate the command voltage for the nonlinearity.Thirdly,the effect of current estimation error on the calculated voltage compensation value is analyzed.The analysis shows that even if the current estimation error exists,the average error of the voltage compensation value based on the estimated current is still 0.Finally,the effect of parameter deviation on the control strategy is analyzed,and the influence of parameter deviation on the optimal voltage command amplitude and the response current is given. The experimental results for steady-state conditions show that the A-phase current fundamental wave amplitude of the motor with the proposed strategy is smaller than that with the traditional strategy.The effectiveness of the proposed method is verified.The experimental results at the same load torque under different speeds show that the current vector amplitude error of the MTPA control with the proposed method is small.Its maximum error does not exceeding 0.5%,while the traditional method is 14%~30%.The experimental results at the same speed with different load torques show that the current vector magnitude error of MTPA control with the proposed method is small,with the maximum error not exceeding 1%.In contrast,the traditional method's maximum error is in the range of 2%~37%.The experimental results of dynamic operation and loaded starting conditions show that the proposed control strategy is robust to parameter deviations and has good dynamic performance. The following conclusions can be drawn.(1)The proposed method can realize MTPA control of IPMSM without current sensors,which is of great significance to the fault-tolerant control capability of current sensor failures in the IPMSM drive system.(2)The proposed method has good dynamic performance and is robust in the variation of motor parameters.(3)The proposed MTPA control strategy considers the effect of VSI nonlinearity,and the control voltages are compensated,effectively improving the running accuracy in MTPA.关键词
内置式永磁同步电机/最大转矩电流比/无电流传感器/非线性补偿Key words
Interior permanent magnet synchronous motor(IPMSM)/maximum torque per ampere(MTPA)/current sensorless/nonlinearity compensation分类
信息技术与安全科学引用本文复制引用
许观达,肖飞,连传强,郭力源,刘计龙..考虑VSI非线性影响的内置式永磁同步电机无电流传感器MTPA控制策略[J].电工技术学报,2025,40(10):3131-3142,12.基金项目
国家自然科学基金资助项目(52177202). (52177202)