Abstract
Combined with an engineering example,the technical economy of electric heat storage device coupled with a sewage source heating system is ana-lyzed.Compared with the gas boiler room heating sys-tem,the investment of the coupled heating system is 647.1×104 yuan higher and the annual operating cost is 162.69×104 yuan/a lower.The extra investment of the coupled heating system can be recovered in 4.0 years.关键词
电蓄热装置/污水源热泵/技术经济性Key words