| 注册
首页|期刊导航|宁夏电力|1000MW超超临界锅炉高温再热器爆管原因分析

1000MW超超临界锅炉高温再热器爆管原因分析

张宁

宁夏电力Issue(2):72-76,82,6.
宁夏电力Issue(2):72-76,82,6.DOI:10.3969/j.issn.1672-3643.2025.02.011

1000MW超超临界锅炉高温再热器爆管原因分析

Analysis of tube burst in high-temperature reheater of 1 000 MW ultra-supercritical boiler

张宁1

作者信息

  • 1. 深圳市深汕特别合作区华润电力有限公司,广东 深圳 518000
  • 折叠

摘要

Abstract

An ultra-supercritical boiler has been in service for 26 000 h,and the high temperature reheater pipe made of S30432 material has exploded and leaked during the operation.Through macroscopic inspection,chemical elements analyses,mechanical properties tests,metallographic test,and energy spectrum analysis,and compared with adjacent pipes,the results show that the grain size of the failed pipe is too fine compared with that of the contrast pipe.Under the same high temperature service environment,the second phase precipitates and grows,forms into creep cavities.The metallographic structure is seriously aging,resulting in the material strength and plasticity decline,and finally when the finial strength of a steel pipe fails to meet the required service strength,the tube bursting occured.

关键词

高温再热器/晶粒度/高温蠕变/强度

Key words

high-temperature reheater/grain size/high temperature creep/intensity

分类

动力与电气工程

引用本文复制引用

张宁..1000MW超超临界锅炉高温再热器爆管原因分析[J].宁夏电力,2025,(2):72-76,82,6.

宁夏电力

1672-3643

访问量0
|
下载量0