| 注册
首页|期刊导航|农业工程学报|一种对作物Mg2+活体检测的全固态微针型传感器制备及应用

一种对作物Mg2+活体检测的全固态微针型传感器制备及应用

王志豪 樊成孝 王焯 黄岚 王忠义

农业工程学报2025,Vol.41Issue(9):29-36,8.
农业工程学报2025,Vol.41Issue(9):29-36,8.DOI:10.11975/j.issn.1002-6819.202410108

一种对作物Mg2+活体检测的全固态微针型传感器制备及应用

Development and application of an all-solid-state Mg2+microneedle sensor for crop in-situ detection

王志豪 1樊成孝 1王焯 2黄岚 2王忠义1

作者信息

  • 1. 中国农业大学信息与电气工程学院,北京 100083||现代精细农业系统集成研究教育部重点实验室,北京 100083
  • 2. 中国农业大学信息与电气工程学院,北京 100083||农业农村部农业信息获取技术重点实验室,北京 100083
  • 折叠

摘要

Abstract

A microneedle all-solid-state selective electrode(ASS-ISE)was developed to rapidly in-situ detect Mg2+in the crop stems.The electrode consists 3 parts from the inner to the outer layer,consisting of stainless-steel microneedle,solid contact and ion ion-selective membrane(ISM).This sensor was prepared as follows.Firstly,a stainless-steel microneedle was used as the conductive substrates.The graphene conductive layer was coated on the tip of the microneedle after drying for 12 h.And then,a solid-state contact of Poly(3,4-ethylenedioxythiophene)/Poly(styrene sulfonate,PEDOT/PSS)was electroplated onto the graphene surface;After the second drying for 12 h,an ion selective membrane(ISM)was coated on the tip of the microneedle;The sensor was fabricated after the third drying time of 12 h and activation.A series of the accurate measurements were carried out on the sensor.Initially,the sensor was calibrated using a standard concentration of MgCl2 solution.The performance of the graphene-PEDOT solid-state contact was tested using scanning electron microscopy(SEM),water layer test,and electrochemical impedance spectroscopy(EIS).A comparison test was then made on two types of sensors,the needle-graphene-PEDOT-ISM and the needle-ISM sensors.Finally,the sensor was applied to detect the Mg2+in wheat seedling stalks.Both pure agar and deionized water were used to verify the reliability of the detection.The potentiometric calibration demonstrated that the sensor exhibited a rapid response with a response time of 7.0 s,and a detection limit as low as 1.0×10-7 mol/L.The better detection was achieved with a Nernst slope of 27.04 mV/dec and a lifetime of at least 30 days.The SEM test demonstrated that the graphene-PEDOT solid-state contact was substantially improved in the low-frequency capacitance between the ion-selective membrane and the stainless-steel substrate.The water layer test demonstrated that the graphene-PEDOT solid-state contact was effectively inhibited the formation of the water layer for the high stability of the ion-electron transfer of the sensor,thus reducing the signal drift.The EIS fitting test showed that there were the similar equivalent circuit diagrams of the two types of sensors.In addition,the graphene-PEDOT solid-state contact structure was effectively reduced the charge transfer resistance on the sensor surface.The stability of the response potential was improved during the process.The sensor was performed best to detect the concentration of Mg2+in the stems of the wheat seedlings in the range of about 1.0×10-3.42-10-3.03 mol/L.In summary,a wide range of the promising prospects was also gained in the low detection limit,the stable potential response,in-situ detection of Mg2+concentration in the crop stalks.

关键词

传感器/作物Mg2+检测/石墨烯/电位校准

Key words

sensors/crop Mg2+detection/graphene/potential calibration

分类

化学

引用本文复制引用

王志豪,樊成孝,王焯,黄岚,王忠义..一种对作物Mg2+活体检测的全固态微针型传感器制备及应用[J].农业工程学报,2025,41(9):29-36,8.

基金项目

国家重点研发计划(2022YFD2002300) (2022YFD2002300)

农业工程学报

OA北大核心

1002-6819

访问量1
|
下载量0
段落导航相关论文