双能量CT虚拟单能成像在早期胃癌定位钛夹伪影消除中的作用

李欢欢 刘壮 陈超 王丽丽 顾雅佳

中国临床医学2025,Vol.32Issue(3):376-383,8.
中国临床医学2025,Vol.32Issue(3):376-383,8.DOI:10.12025/j.issn.1008-6358.2025.20240932

双能量CT虚拟单能成像在早期胃癌定位钛夹伪影消除中的作用

The role of dual-energy CT virtual monoenergetic imaging in eliminating artifacts caused by metallic clips in early gastric cancer

李欢欢 1刘壮 1陈超 1王丽丽 2顾雅佳1

作者信息

  • 1. 复旦大学附属肿瘤医院放射诊断科,上海 200032
  • 2. 上海中医药大学附属曙光医院核医学科,上海 201203
  • 折叠

摘要

Abstract

Objective To evaluate the image quality of abdominal dual-energy CT virtual monoenergetic imaging(VMI)in patients with early gastric cancer using titanium alloy clips and assess its effectiveness on reducing metal artifacts.Methods A retrospective study was conducted,including 31 patients with gastric cancer who underwent abdominal dual-energy CT scans with titanium clips inserted in the gastric cavity.Each scan was reconstructed into mixed images(simulated 120 kVp CT)and VMIs with energy levels ranging from 40 keV to 140 keV.Metal artifacts were quantitatively evaluated by measuring the noise values in the lesion and perigastric regions.The contrast-noise ratio(CNR)of the lesion and the corresponding liver tissue was calculated to assess the image quality.Two radiologists independently evaluated the images,considering overall quality,artifact severity,lesion conspicuity,perigastric clarity,and vascular contrast.Results Quantitative analysis revealed that metal artifacts in both the lesion and perigastric regions decreased as the energy level increased.VMIs at 80-140 keV(lesion site)and 90-140 keV(perigastric space)showed significantly fewer artifacts compared to mixed images(P<0.05).The CNR of lesions remained stable across VMIs at 50-140 keV,while the CNR of normal liver tissue decreased significantly with increasing energy(P<0.05).In the subjective assessment,VMIs at 80-140 keV had higher artifact scores than mixed images(P<0.05).VMIs at 70-90 keV provided better lesion conspicuity and perigastric clarity,although vascular contrast decreased significantly with increasing energy(P<0.05).VMIs at 70-90 keV showed better overall quality(P<0.05),though not significantly different from mixed images.Conclusions VMIs at 80 keV and 90 keV improve the visibility of lesions and perigastric regions affected by metallic clips,which combined with mixed images can enhance radiologists'diagnostic accuracy.

关键词

胃癌/定位夹/双能量CT/虚拟单能成像

Key words

gastric cancer/metallic clip/dual-energy CT/virtual monoenergetic imaging

分类

医药卫生

引用本文复制引用

李欢欢,刘壮,陈超,王丽丽,顾雅佳..双能量CT虚拟单能成像在早期胃癌定位钛夹伪影消除中的作用[J].中国临床医学,2025,32(3):376-383,8.

基金项目

国家自然科学基金(82202102),上海市卫生健康委员会青年项目(20224Y0237).Supported by National Natural Science Foundation of China(82202102)and Youth Project of Shanghai Municipal Health Commission(20224Y0237). (82202102)

中国临床医学

1008-6358

访问量0
|
下载量0
段落导航相关论文