| 注册
首页|期刊导航|国际眼科杂志|运用眼表综合分析仪分析高龄人群白内障术前角膜曲率值

运用眼表综合分析仪分析高龄人群白内障术前角膜曲率值

蒋洪 郝亚静 高艺 叶子

国际眼科杂志2025,Vol.25Issue(7):1167-1171,5.
国际眼科杂志2025,Vol.25Issue(7):1167-1171,5.DOI:10.3980/j.issn.1672-5123.2025.7.22

运用眼表综合分析仪分析高龄人群白内障术前角膜曲率值

Analysis of preoperative corneal curvature in elderly cataract patients using an ocular surface comprehensive analyzer

蒋洪 1郝亚静 2高艺 1叶子1

作者信息

  • 1. (100039)中国北京市,中国人民解放军总医院第一医学中心眼科
  • 2. (100039)中国北京市,中国人民解放军总医院第二医学中心眼科
  • 折叠

摘要

Abstract

AIM:To measure preoperative corneal curvature in elderly cataract patients using five different systems,including Keratograph 5M,Pentacam,KR.800 autorefractor,IOL Master,and KR-1W wavefront aberrometer,analyze its discrepancy and consistency,and provide a reference for accurate intraocular lens(IOL)power calculation in elderly patients before cataract surgery. METHODS:This prospective study included 53 elderly cataract in-patients(90 eyes)who were admitted to our ophthalmology department between October 2022 and November 2024.The corneal curvature values(K1,K2)of postoperative eyes were measured using Keratograph 5M,Pentacam,KR.800,IOL Master,and KR-1W,and the mean keratometry(Km)was calculated. RESULTS:Statistically significant differences were observed in K1,K2,and Km values between Keratograph 5M and Pentacam,as well as between Keratograph 5M and IOL Master(all P<0.05),whereas no significant differences were found in K1,K2 and Km between Keratograph 5M and KR.800 or KR-1W(all P>0.05).Pearson correlation analysis showed a certain correlation of K1,K2 and Km obtained from Keratograph 5M with those from KR.800,Pentacam,IOL Master,and KR-1W(r=0.913-0.987,all P<0.001).Bland-Altman scatter plots demonstrated good consistency between Keratograph 5M and KR.800 or KR-1W,while its consistency with Pentacam and IOL Master was relatively poor. CONCLUSION:As an ocular surface analyzer,Keratograph 5M offers advantages such as simplicity,rapid measurement,strong repeatability,and low patient cooperation requirements.In elderly patients,corneal curvature measurements obtained by Keratograph 5M demonstrated good consistency with those from KR.800 and KR-1W,making them interchangeable based on individual conditions and cooperation levels of patients.However,its consistency with Pentacam and IOL Master was relatively poor;therefore,clinical practical situation should be considered when selecting such measurement devices.

关键词

角膜曲率/白内障/IOL Master/Keratograph 5M/Pentacam

Key words

corneal curvature/cataract/IOL Master/Keratograph 5M/Pentacam

引用本文复制引用

蒋洪,郝亚静,高艺,叶子..运用眼表综合分析仪分析高龄人群白内障术前角膜曲率值[J].国际眼科杂志,2025,25(7):1167-1171,5.

国际眼科杂志

1672-5123

访问量4
|
下载量0
段落导航相关论文