Abstract

During the process of the control and inspection of the train control center in the tuning zone,the problem of red-light straps arises,caused by bad shunting due to the presence of the last train wheelset in a tuning zone.The operation of the trains and the causes of the red-light straps are analyzed.Four solutions are proposed for the problem of flashing red-light straps.After comprehensive consideration,it is recommended to optimize the parking position of a train outside a signal from the perspective of train management to prevent the front and rear end of the train from stopping in a tuning zone.This change can eradicate the flashing red-light problem caused by a train waiting outside a signal.

关键词

机外等排/调谐区纳入控制检查/红光带

Key words

waiting outside the signal/tuning zone included in the control and inspection by the train control center/red-light strap