| 注册
首页|期刊导航|节能|新风系统管道设计及其换热器流场分析

新风系统管道设计及其换热器流场分析

黄忠文 李聪学 马天茨 赵匡延 郭时敏 徐钦旭

节能2025,Vol.44Issue(4):69-72,4.
节能2025,Vol.44Issue(4):69-72,4.DOI:10.3969/j.issn.1004-7948.2025.04.017

新风系统管道设计及其换热器流场分析

Pipeline design of fresh air system and flow field analysis of heat exchanger

黄忠文 1李聪学 1马天茨 1赵匡延 1郭时敏 1徐钦旭1

作者信息

  • 1. 武汉工程大学机电工程学院,湖北 武汉 430205||湖北省绿色化工装备工程技术研究中心,湖北 武汉 430205
  • 折叠

摘要

Abstract

In order to solve the problems of high energy loss and low energy utilization of fresh air system,the structural design of fresh air system pipeline was optimized.The Taguchi experiment method was used to design the trumpet tuyere with different angles(30°,45°,60°)between the inclined plane of the horn and the normal direction of the roof.The changes of wind speed under different angles were compared and analyzed,and the flow field of the heat exchanger was analyzed by CFD.The results show that when the angle between the horn slope and the normal direction of the roof is 45°,the heat transfer effect is the best,and the average wind speed increases to 0.68 m/s.The flow field of heat exchanger is analyzed by CFD,and the heat transfer effect is obviously enhanced after the interference plate is added.When the filter layer is 2 layers,the effect on wind speed and air quality is small.At 2 m/s and 5 m/s air flow rates,the steady wind speed at the outlet center increased by 33.3%and 24.4%,respectively.

关键词

新风系统/换热器/节能

Key words

fresh air system/heat exchanger/energy-saving

分类

能源科技

引用本文复制引用

黄忠文,李聪学,马天茨,赵匡延,郭时敏,徐钦旭..新风系统管道设计及其换热器流场分析[J].节能,2025,44(4):69-72,4.

节能

1004-7948

访问量0
|
下载量0