| 注册
首页|期刊导航|中国感染控制杂志|口腔诊室鼠标垫污染情况及干预措施研究

口腔诊室鼠标垫污染情况及干预措施研究

卢策 任红润 李淑媛 车明清 高涛 王莉蓉

中国感染控制杂志2025,Vol.24Issue(6):789-794,6.
中国感染控制杂志2025,Vol.24Issue(6):789-794,6.DOI:10.12138/j.issn.1671-9638.20256725

口腔诊室鼠标垫污染情况及干预措施研究

Contamination of mouse pads in dental clinics and its intervention measures

卢策 1任红润 1李淑媛 1车明清 1高涛 1王莉蓉1

作者信息

  • 1. 南京大学医学院附属口腔医院南京大学口腔医学研究所南京市口腔医院感染管理科,江苏南京 210008
  • 折叠

摘要

Abstract

Objective To investigate the contamination status of cloth mouse pads in dental clinics,and provide theoretical basis for standardizing environmental surface disinfection and scientific intervention in dental clinics.Methods The contamination status of cloth mouse pads in 5 dental clinics were investigated by adenosine triphos-phate(ATP)fluorescence detection method,visual observation method,and bacterial culture method.Disinfection efficacy of ultraviolet disinfection method and wiping disinfection using two types of disinfectant wipes on cloth mouse pads and photovoltaic glass mouse pads was compared.Intervention measures(using photovoltaic glass mouse pads,regular cleaning and disinfecting)were taken,and contamination status of cloth mouse pads in different departments before and after intervention was compared.Results The baseline investigation found that the conta-mination status of mouse pads varied in different dental clinics.The qualified rate of bacterial culture of mouse pads in department of endodontics was the lowest(20.00%),followed by the department of periodontology(30.00%).There was statistically significant difference in ATP detection values between two types of disinfectant wipes before and after wiping and disinfecting photovoltaic glass mouse pads(both P<0.001).After using photovoltaic glass mouse pads,the contamination of mouse pads in 5 dental clinics was alleviated,and the qualified rate of ATP detec-tion increased(>80%),compared with qualified rate of ATP detection before intervention,differences were all sta-tistically significant(all P<0.001).Conclusion The contamination of the cloth mouse pads in dental clinics is seri-ous,and the conventional cloth mouse pad is difficult to be cleaned and disinfected.It is suggested that medical in-stitutions use the mouse pad which is convenient for cleaning and disinfection,and specify the disinfection method and frequency to control the contamination of the mouse pads.

关键词

ATP检测/鼠标垫/口腔诊室/消毒

Key words

ATP detection/mouse pad/dental clinic/disinfection

分类

医药卫生

引用本文复制引用

卢策,任红润,李淑媛,车明清,高涛,王莉蓉..口腔诊室鼠标垫污染情况及干预措施研究[J].中国感染控制杂志,2025,24(6):789-794,6.

基金项目

江苏省医院协会医院管理创新研究课题(JSYGY-3-2024-180) (JSYGY-3-2024-180)

江苏省卫生健康委员会预防医学课题面上项目(Ym2023005) (Ym2023005)

南京市科学技术协会"软科学研究"项目(2023-26) (2023-26)

中国感染控制杂志

OA北大核心

1671-9638

访问量0
|
下载量0
段落导航相关论文