煤气与热力2025,Vol.45Issue(7):1-5,18,6.
地热能耦合燃气锅炉房供热系统运行策略
Operation Strategy of Heating System Integrating Geothermal Energy with Gas Boiler Room
张磊 1刘丹 2贺璠 1刘家旺3
作者信息
- 1. 中国市政工程华北设计研究总院有限公司第六设计研究院,天津 300381
- 2. 天津市联合环保工程设计有限公司,天津 300191
- 3. 威海热电集团有限公司,山东 威海 264200
- 折叠
摘要
Abstract
An engineering case study of a heating sys-tem integrating deep geothermal energy with gas boiler room was conducted,in which nine heating capacity scenarios were developed through adjustment of boiler output,with operational strategies being evaluated for maximizing geothermal well utilization while minimiz-ing reinjection temperature.Compared with the opera-tion strategy of constant flow of geothermal water with a designed mass flow rate and less strict requirements on reinjection temperature,the utilization rate of geother-mal wells with variable flow rate of geothermal water with a reinjection temperature not exceeding the suit-able reinjection temperature during heating period has decreased,but the reinjection temperature is more rea-sonable.Therefore,it is appropriate to adopt the vari-able flow operation strategy of geothermal water with a reinjection temperature not exceeding the appropriate reinjection temperature during heating period.The utili-zation rate of geothermal wells reaches 98.45%at 0.5 boiler capacity ratio and achieves 100%at ≥1.00 ratio.关键词
中深层地热能/燃气锅炉房/地热井利用率/回灌温度Key words
mid-deep geothermal energy/gas boiler room/utilization rate of geothermal wells/reinjection temperature分类
建筑与水利引用本文复制引用
张磊,刘丹,贺璠,刘家旺..地热能耦合燃气锅炉房供热系统运行策略[J].煤气与热力,2025,45(7):1-5,18,6.